Thanks Kelly!  Looked at these def files with a great little tool called 
"ExamDiff" and forms, filters, AL and Menus are all the same.  There is no 
difference.  BMC is still looking into this as well.


Lisa



________________________________
From: Action Request System discussion list(ARSList) 
[mailto:[email protected]] On Behalf Of Kelly Deaver
Sent: Thursday, February 18, 2010 9:09 AM
To: [email protected]
Subject: Re: Importing Definition Forms

**
I would identify a filter, active link, and form  on each server where they 
both have the same timestamp for last updated (they are both the same from 
BMC). Now compare the two export files. Is there something different? This may 
give you a clue.

Kelly Deaver
L-3 Stratis / FAA Contractor
[email protected] (ARSlist mail)
[email protected]<mailto:[email protected]> (Business mail)


-------- Original Message --------
Subject: Re: Importing Definition Forms
From: Joe D'Souza <[email protected]>
Date: Wed, February 17, 2010 2:35 pm
To: [email protected]

**
Lisa,

Since it may be a while before you have the luxury of restarting production why 
not try this..

Have you tried exporting it in a different format? Instead of a regular def 
file, take an XML export. See if you get the same error..

Joe
-----Original Message-----
From: Action Request System discussion list(ARSList) 
[mailto:[email protected]]on Behalf Of Coleman, Gavin
Sent: Wednesday, February 17, 2010 9:28 AM
To: [email protected]
Subject: Re: Importing Definition Forms

**
Hi Lisa - I have indeed seen this error. It has occurred several times on our 
development servers (ARS 6.3 patch 24), but I've never been able to determine 
the root cause of the problem. My only solution is to restart the Remedy 
application. This seems to clear the error and you are then able to import 
definition files without error.
Given that this is a production system, this may be unpalatable, but this is 
the only solution I have found!
Thanks,
Gavin Coleman
Senior Analyst/Programmer
Computacenter (UK) Ltd
Services & Solutions
Hatfield Avenue
Hatfield, Hertfordshire, AL10 9TW, United Kingdom
T: +44 (0) 1707 631662
E: [email protected]<mailto:[email protected]>
W: www.computacenter.com<http://www.computacenter.com/>
From: Action Request System discussion list(ARSList) 
[mailto:[email protected]] On Behalf Of Kemes, Lisa
Sent: 17 February 2010 13:51
To: [email protected]
Subject: Importing Definition Forms
**
We are having a really bizarre issue with importing any form, active link, 
filter or escalation from our Development Server to our Production Server.  
Both are at the same version (ARS 7.1 P7).  Both DB's are at the same version 
Oracle 10g.  And both servers are Windows 2003 boxes.  We try to take great 
care in keeping both boxes exactly the same.
I tried a simple form with a menu, a filter, and an active link.  They wouldn't 
load.  It generated the following errors.
The file specified for a character menu does not hold a character menu 
definition:  (ARERR 414)
The file specified for an active link does not hold an active link definition:  
(ARERR 413)
I tried the menu alone.  It errored.
When I tried to just import the form I would get:
The following item was not imported: Junk (ARERR 55)
The file specified for a character menu does not hold a character menu 
definition:  (ARERR 414)
The file specified for an active link does not hold an active link definition:  
(ARERR 413)
Has anyone ever seen this issue before?
When I export from Dev and import back into Dev, it's fine.  As of yesterday 
morning, when I exported from Prod and imported back into Prod, everything is 
fine.  It's when I try to export from Dev into Prod.
Lisa Kemes
AR System Developer
Tyco Electronics
717-810-2408 tel
717-810-2124 fax
[email protected]
_Platinum Sponsor: [email protected] ARSlist: "Where the Answers Are"_

**********************************************************************
COMPUTACENTER PLC is registered in England and Wales with the registered number 
03110569. Its registered office is at Hatfield Business Park, Hatfield Avenue, 
Hatfield, Hertfordshire AL10 9TW
COMPUTACENTER (UK) Limited is registered in England and Wales with the 
registered number 01584718. Its registered office is at Hatfield Business Park, 
Hatfield Avenue, Hatfield, Hertfordshire AL10 9TW
COMPUTACENTER (Mid-Market) Limited is registered in England and Wales with the 
registered number 3434654. Its registered office is at Hatfield Business Park, 
Hatfield Avenue, Hatfield, Hertfordshire AL10 9TW
COMPUTACENTER (FMS) Limited is registered in England and Wales with the 
registered number 3798091. Its registered office is at Hatfield Business Park, 
Hatfield Avenue, Hatfield, Hertfordshire AL10 9TW

The contents of this email are intended for the named addressee only.
It contains information which may be confidential and which may also be 
privileged.
Unless you are the named addressee (or authorised to receive mail for the 
addressee) you may not copy or use it, or disclose it to anyone else.
If you receive it in error please notify us immediately and then destroy it.
Computacenter information is available from: http://www.computacenter.com
**********************************************************************
_Platinum Sponsor: [email protected] ARSlist: "Where the Answers Are"_