I decided to use y=[1 reg_raw_value]*b to get the ``surface'' temperature
after some tests.
for it look more reasonable than (reg_raw_value-1447)*100
b =[
-263.2669
0.1281
]
<https://lh6.googleusercontent.com/-YfPXOU1vBxE/U6CdpwLONbI/AAAAAAAABx8/8yEEnsuAo6k/s1600/res.png>
<https://lh6.googleusercontent.com/-YfPXOU1vBxE/U6CdpwLONbI/AAAAAAAABx8/8yEEnsuAo6k/s1600/res.png>
<https://lh6.googleusercontent.com/-pkpTzrdSUvo/U6IcjqFJuSI/AAAAAAAAByU/KYW8ekR0n1Q/s1600/templog.png>
here is the raw data i collected
https://www.dropbox.com/s/e2fgzpene2d8d7j/data.csv.bz2
--
You received this message because you are subscribed to the Google Groups
"linux-sunxi" group.
To unsubscribe from this group and stop receiving emails from it, send an email
to [email protected].
For more options, visit https://groups.google.com/d/optout.