With respect to the use of PREGAP in the Cue Sheet.  It should be optional. 
When not included prior to the first INDEX statement I understand that an 
automatic pregap of 2 seconds is created prior to track 1.  With CDRWin I never 
do use a pregap statement and that is what I observe.
With my original 'Large.cue' I do not use a PREGAP statement and get successful 
burns on all 9 drives with CD-RW discs and on 4 of 9 with CD-R discs.
Without the PREGAP statement this is an excerpt of the debug log for LG_E60N
00:48.75: > Sending CUE sheet...
00:48.84: > cdrecord: CUE sheet not accepted. Retrying with minimum pregapsize 
= 1.
01:28.47: > cdrecord: Input/output error. write_g1: scsi sendcmd: no error
01:28.47: > CDB:  2A 00 FF FF D1 B7 00 02 9F 00
01:28.48: > status: 0x2 (CHECK CONDITION)
01:28.48: > Sense Bytes: 70 00 04 00 00 00 00 0E 00 00 00 00 09 00 00 00 00 00
01:28.48: > Sense Key: 0x4 Hardware Error, Segment 0
01:28.50: > Sense Code: 0x09 Qual 0x00 (track following error) Fru 0x0
01:28.50: > Sense flags: Blk 0 (not valid) 
01:28.50: > cmd finished after 39.624s timeout 200s
01:28.50: > cdrecord: Could not write Lead-in.
01:28.58: > SAO startsec: -11849
01:28.58: > Writing lead-in...
01:28.58: > write CD-Text data: error after 0 bytes
01:28.59: > Writing  time:   39.873s (00:00:39.873)
01:28.59: > cdrecord: fifo had 64 puts and 0 gets.
01:28.59: > cdrecord: fifo was 0 times empty and 0 times full, min fill was 
100%.
01:28.61: > 
01:28.61: > Execution completed.
I have added the PREGAP statement, using 'Large_added_pregap.cue', here is an 
excerpt:
    PREGAP 00:02:00
    INDEX 01 00:00:00
With this added PREGAP statement thhis is an excerpt of the debug log for 
LG_E60N
00:48.48: > Sending CUE sheet...
00:48.59: > cdrecord: CUE sheet not accepted. Retrying with minimum pregapsize 
= 1.
01:27.95: > cdrecord: Input/output error. write_g1: scsi sendcmd: no error
01:27.95: > CDB:  2A 00 FF FF D1 B7 00 02 9F 00
01:27.97: > status: 0x2 (CHECK CONDITION)
01:27.97: > Sense Bytes: 70 00 04 00 00 00 00 0E 00 00 00 00 09 00 00 00 00 00
01:27.97: > Sense Key: 0x4 Hardware Error, Segment 0
01:27.97: > Sense Code: 0x09 Qual 0x00 (track following error) Fru 0x0
01:27.98: > Sense flags: Blk 0 (not valid) 
01:27.98: > cmd finished after 39.358s timeout 200s
01:27.98: > cdrecord: Could not write Lead-in.
01:28.06: > SAO startsec: -11849
01:28.06: > Writing lead-in...
01:28.06: > write CD-Text data: error after 0 bytes
01:28.08: > Writing  time:   39.608s (00:00:39.608)
01:28.08: > cdrecord: fifo had 64 puts and 0 gets.
01:28.08: > cdrecord: fifo was 0 times empty and 0 times full, min fill was 
100%.
01:28.09: > 
01:28.09: > Execution completed.
The results are the same.
Perhaps cdrtfe is mangling the cue sheets in some manner..however I currently 
do now know this.
I provided links to the cue sheets as I do not know if the mailing list allows 
attachments.
But I will attach the cue sheets and perhaps they will be accepted.
Ron Stordahl








Attachment: Large_added_pregap.cue
Description: Binary data

Attachment: Large.cue
Description: Binary data

------------------------------------------------------------------------------
Site24x7 APM Insight: Get Deep Visibility into Application Performance
APM + Mobile APM + RUM: Monitor 3 App instances at just $35/Month
Monitor end-to-end web transactions and take corrective actions now
Troubleshoot faster and improve end-user experience. Signup Now!
http://pubads.g.doubleclick.net/gampad/clk?id=272487151&iu=/4140
_______________________________________________
Cdrtools-support mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/cdrtools-support

Reply via email to