Hi Brett,

I mean to say in second or third 183 w/SDP "TO" tag is same but "RSeq:
2779" is incrementing.

I am sorry but i am still not clear on second part, is that 2~3 183 w/sdp
is valid and call can be processed? As you mentioned if UAS sends the 183
w/SDP where it is requesting for PRACK again then UAC can be prepare to
receive SDP. Also it can ignore it.

Regards,
Nitin Kapoor




On Thu, Jul 10, 2014 at 1:07 PM, Brett Tate <[email protected]> wrote:

> > As per this paragraph and i checked the RFC..
> > Which means UAS can send additional 183 w/SDP
> > or RSEQ, and UAC simply can ignore this.
>
> I'm not sure what you mean by "or RSEQ".
>
> The UAC does not ignore the 18x.  The RFC's indicate to ignore the SDP
> since
> it is not officially a new offer or answer.
>