> On Sept. 28, 2013, 1:59 a.m., Jacopo De Simoi wrote:
> > Let me have a look at the patch; I'll be able to do it tomorrow and commit 
> > it myself if it is ok. 
> > 
> > Thanks
> > 
> > __J 
> > Device notifier mantainer

Ok, even with the patch, within any given category (e.g. Storage Volume) 
devices are sorted in essentially random order (that is, the population order 
of the engine), so the patch is not addressing that issue.  On the other hand 
it surely helps a lot to have Network devices and Storage Volumes separated in 
the list when showing only non-removable devices.  
I still believe it is useful to have removable devices show up on top of other 
ones when showing all devices, so I am not convinced of changing the sort-order 
in this case. 

I would therefore change the sort order only if showing “non-removable devices 
only” and I am willing to commit this change if it is ok with the author. 

Still, a true solution is still to be found, so I'd rather not close the bug 
quite yet. 


- Jacopo De


-----------------------------------------------------------
This is an automatically generated e-mail. To reply, visit:
http://git.reviewboard.kde.org/r/112812/#review40934
-----------------------------------------------------------


On Sept. 19, 2013, 3:24 p.m., Benedikt Gollatz wrote:
> 
> -----------------------------------------------------------
> This is an automatically generated e-mail. To reply, visit:
> http://git.reviewboard.kde.org/r/112812/
> -----------------------------------------------------------
> 
> (Updated Sept. 19, 2013, 3:24 p.m.)
> 
> 
> Review request for Plasma.
> 
> 
> Description
> -------
> 
> Use type description sort order in the devicenotifier applet when 
> non-removable devices are configured to be displayed. This avoids apparently 
> random sort order (by device engine population timestamp) and unneccessary 
> ListView sections. The problem becomes apparent if other types of devices 
> besides simple storage volumes are configured in /etc/fstab, like for example 
> network mounts.
> 
> Fixes bug #324459.
> 
> 
> This addresses bug 324459.
>     http://bugs.kde.org/show_bug.cgi?id=324459
> 
> 
> Diffs
> -----
> 
>   
> plasma/generic/applets/devicenotifier/package/contents/ui/devicenotifier.qml 
> 9b6132e 
> 
> Diff: http://git.reviewboard.kde.org/r/112812/diff/
> 
> 
> Testing
> -------
> 
> Works for me using KDE 4.10.5 packaged with Fedora 19.
> 
> 
> Thanks,
> 
> Benedikt Gollatz
> 
>