jjorge added a comment.

  > How can you interpret these weird charge_now values correctly? If the range 
is [1/1000, 901] Wh, while the real range is [0, 45] Wh, how does the charge 
curve look like while charging or discharging? Are there (continues) values in 
[46, 901] Wh? Do you assume all of those as 100%?
  
  The only correct interpretation is that a battery chan't have 2000% charge, 
neither -45%. So we assume the 0-100 range for a percentage ;-)
  
  Edit: Is the charge_now or the maximum value incorrect due a faulty battery?
  
  Yes, that's the reason. The BIOS tells me I should junk it, but I can still 
work nearly two hours more when it is plugged in ;-)