Arun,
   I have enabled the requested TRACE logs and running the CSIT now.
   Ever since I enabled the TRACEs it has not failed :).
   Let us see if the issue gets reproduced in another 24 hours.
Thanks,
Faseela

From: D Arunprakash
Sent: Wednesday, July 25, 2018 7:53 AM
To: Faseela K <[email protected]>; Anil Vishnoi <[email protected]>
Cc: Gobinath . <[email protected]>; Sam Hague <[email protected]>; 
Dayavanti Gopal Kamath <[email protected]>; Jamo Luhrsen 
<[email protected]>; Vishal Thapar <[email protected]>; 
[email protected]
Subject: RE: Netvirt Cluster CSIT : Table Miss Entry programming failing 
randomly

Faseela,
Could you please enable the following package logging and provide the logs?

log:set DEBUG org.opendaylight.openflowplugin.impl

Regards,
Arun

From: Faseela K
Sent: Tuesday, July 24, 2018 11:44 PM
To: Anil Vishnoi <[email protected]<mailto:[email protected]>>
Cc: D Arunprakash 
<[email protected]<mailto:[email protected]>>; Gobinath . 
<[email protected]<mailto:[email protected]>>; Sam Hague 
<[email protected]<mailto:[email protected]>>; Dayavanti Gopal Kamath 
<[email protected]<mailto:[email protected]>>;
 Jamo Luhrsen <[email protected]<mailto:[email protected]>>; Vishal Thapar 
<[email protected]<mailto:[email protected]>>; 
[email protected]<mailto:[email protected]>
Subject: RE: Netvirt Cluster CSIT : Table Miss Entry programming failing 
randomly

Hi Arun,
    We are still hitting this issue, and this can be seen on stable/oxygen as 
well.
     In some cases the flow will be programmed initially, but after some time 
it disappears.

     I do see a lot of "Switch Idle state occurred, 
node=/10.30.170.51:60858|auxId=0" messages in the logs. Is that anything to 
worry about?

  If there is any specific TRACE logs to be enabled while running the CSIT, 
could you please let me know? I can run the CSIT with the same and supply the 
logs.
Thanks,
Faseela

From: Faseela K
Sent: Tuesday, July 17, 2018 1:24 PM
To: Anil Vishnoi <[email protected]<mailto:[email protected]>>
Cc: D Arunprakash 
<[email protected]<mailto:[email protected]>>; Gobinath . 
<[email protected]<mailto:[email protected]>>; Sam Hague 
<[email protected]<mailto:[email protected]>>; Dayavanti Gopal Kamath 
<[email protected]<mailto:[email protected]>>;
 Jamo Luhrsen <[email protected]<mailto:[email protected]>>; Vishal Thapar 
<[email protected]<mailto:[email protected]>>; 
[email protected]<mailto:[email protected]>
Subject: Netvirt Cluster CSIT : Table Miss Entry programming failing randomly

Anil,

I have raised the below JIRA, where I see Table Miss flow for Table 43 is 
sometimes not getting programmed on one of the computes in netvirt 3 node CSIT.
https://jira.opendaylight.org/browse/OPNFLWPLUG-1028
I do see flow being pushed to config/inventory by netvirt, but it is missing on 
switch.
This makes the basic DHCP itself fail for netvirt as this is one of the 
important flows needed for all broadcasts to work.
Any pointers?