From: DENG Qingfang <[email protected]>
Date: Tue,  8 Dec 2020 15:00:28 +0800

> MT7530 has a global address age control register, so use it to set
> ageing time.
> 
> The applied timer is (AGE_CNT + 1) * (AGE_UNIT + 1) seconds
> 
> Signed-off-by: DENG Qingfang <[email protected]>

Applied, thanks