On Tue, Dec 08, 2020 at 03:00:28PM +0800, DENG Qingfang wrote:
> MT7530 has a global address age control register, so use it to set
> ageing time.
> 
> The applied timer is (AGE_CNT + 1) * (AGE_UNIT + 1) seconds
> 
> Signed-off-by: DENG Qingfang <[email protected]>

Reviewed-by: Andrew Lunn <[email protected]>

    Andrew