On Tue, 20 Oct 2020 17:51:26 +0200 Andrew Lunn <and...@lunn.ch> wrote:
> > @@ -2006,6 +2040,23 @@ static int sfp_sm_mod_probe(struct sfp *sfp, bool > > report) > > > > sfp->id = id; > > > > + sfp->phy_addr = SFP_PHY_ADDR; > > + > > + rollball = ((!memcmp(id.base.vendor_name, "OEM ", 16) || > > + !memcmp(id.base.vendor_name, "Turris ", 16)) && > > + (!memcmp(id.base.vendor_pn, "SFP-10G-T ", 16) || > > + !memcmp(id.base.vendor_pn, "RTSFP-10", 8))); > > Are you customising the SFP, so that it has your vendor name? > > Is the generic SFP OEM/SFP-10G-T, and your customized one Turris/ > RTSFP-10? > > Andrew Hilink puts OEM/SFP-10G-T into their modules. RollBall puts OEM/RTSFP-10 and sometimes OEM/RTSFP-10G. They are rebranding these modules for us to Turris/RTSFP-10. Marek