On Tue, 20 Oct 2020 17:51:26 +0200
Andrew Lunn <and...@lunn.ch> wrote:

> > @@ -2006,6 +2040,23 @@ static int sfp_sm_mod_probe(struct sfp *sfp, bool 
> > report)
> >  
> >     sfp->id = id;
> >  
> > +   sfp->phy_addr = SFP_PHY_ADDR;
> > +
> > +   rollball = ((!memcmp(id.base.vendor_name, "OEM             ", 16) ||
> > +                !memcmp(id.base.vendor_name, "Turris          ", 16)) &&
> > +               (!memcmp(id.base.vendor_pn, "SFP-10G-T       ", 16) ||
> > +                !memcmp(id.base.vendor_pn, "RTSFP-10", 8)));  
> 
> Are you customising the SFP, so that it has your vendor name?
> 
> Is the generic SFP OEM/SFP-10G-T, and your customized one Turris/ 
> RTSFP-10?
> 
>       Andrew

Hilink puts OEM/SFP-10G-T into their modules.
RollBall puts OEM/RTSFP-10 and sometimes OEM/RTSFP-10G.
They are rebranding these modules for us to Turris/RTSFP-10.

Marek

Reply via email to