On Tue, 6 Oct 2020 15:52:53 +0200 Marek Vasut wrote:
> The phy_reset_after_clk_enable() does a PHY reset, which means the PHY
> loses its register settings. The fec_enet_mii_probe() starts the PHY
> and does the necessary calls to configure the PHY via PHY framework,
> and loads the correct register settings into the PHY. Therefore,
> fec_enet_mii_probe() should be called only after the PHY has been
> reset, not before as it is now.
>
> Fixes: 1b0a83ac04e3 ("net: fec: add phy_reset_after_clk_enable() support")
> Reviewed-by: Andrew Lunn <[email protected]>
> Tested-by: Richard Leitner <[email protected]>
> Signed-off-by: Marek Vasut <[email protected]>
Is moving the reset before fec_enet_mii_probe() the reason you need the
second patch?
net: fec: Fix phy_device lookup for phy_reset_after_clk_enable()