On Sat, Jul 18, 2020 at 02:37:41AM +0000, Martin Rowe wrote:
> On Fri, 17 Jul 2020 at 21:26, Russell King - ARM Linux admin
> <li...@armlinux.org.uk> wrote:
> > Both ends really need to agree, and I'd suggest cp1_eth2 needs to drop
> > the fixed-link stanza and instead use ``managed = "in-band";'' to be
> > in agreement with the configuration at the switch.
> >
> > Martin, can you modify
> > arch/arm64/boot/dts/marvell/armada-8040-clearfog-gt-8k.dts to test
> > that please?
> 
> eth2 now doesn't come up

Sorry, it should have been ``managed = "in-band-status";'' rather than
just "in-band".

-- 