Hi Thanks for feedback . we will analyze multipathd request to handle this scenario
Thanks Santosh -----Original Message----- From: Linux-PowerEdge <[email protected]> On Behalf Of Klaas Demter Sent: Wednesday, November 4, 2020 8:36 PM To: [email protected] Subject: Re: [Linux-PowerEdge] iDRAC update failure [EXTERNAL EMAIL] we miss the SMINST device, but I don't seem to have encountered that with any updates since I've been using a dell server. I'll write a note to add it if I need to touch the multipath file again. For your more general problem: I once wrote a feature request for dsu to enable it to work with an enabled multipathd, that would (at least from my point of view) be the general solution to this problem :) Greetings Klaas On 11/4/20 3:30 PM, Ben Argyle wrote: > Yes, it turns out this was the one server I'd missed! (-: > > So, sort of 50% my fault! > > Anyway, here seems to be the definitive list at this point (note that there's > one more than you have in > https://github.com/Klaas-/ansible-role-dell-firmware-upgrade/blob/a6a6d1a3c8c18773a5ce3d89f9e68b1693a7d5bd/files/multipath_dell.conf): > > device { > vendor "Linux" > product "scrtch" > } > device { > vendor "iDRAC" > product "scrtch" > } > device { > vendor "DELL" > product "IDSDM" > } > device { > vendor "iDRAC" > product "MAS022" > } > device { > vendor "iDRAC" > product "SECUPD" > } > device { > vendor "iDRAC" > product "SMINST" > } > device { > vendor "Linux" > product "SECUPD" > } > > Best, > > Ben > > -----Original Message----- > From: Linux-PowerEdge <[email protected]> On Behalf Of > Klaas Demter > Sent: 04 November 2020 14:16 > To: [email protected] > Subject: Re: [Linux-PowerEdge] iDRAC update failure > > > [EXTERNAL EMAIL] > > Didn't you already notice that 3 months ago? I seem to recall I added > it to the ansible role because of you :) > > https://github.com/CSCfi/ansible-role-dell-firmware-upgrade/pull/31 > > > > Greetings > > Klaas > > > On 11/4/20 2:44 PM, Ben Argyle wrote: >> [EXTERNAL EMAIL] >> >> I have this in multipath.conf to ensure the new vendor/product USB device(s) >> you keep adding aren't caught by multipathd: >> >> blacklist { >> wwid <WWID of internal disk> >> devnode "^(ram|raw|loop|fd|md|dm-|sr|scd|st)[0-9]*" >> devnode "^hd[a-z]" >> devnode "^cciss!c[0-9]d[0-9]*[p[0-9]*]" >> devnode "^asm/*" >> devnode "ofsctl" >> >> device { >> vendor "iDRAC" >> product "scrtch" >> } >> device { >> vendor "DELL" >> product "IDSDM" >> } >> device { >> vendor "iDRAC" >> product "MAS022" >> } >> device { >> vendor "iDRAC" >> product "SECUPD" >> } >> device { >> vendor "Linux" >> product "SECUPD" >> } >> } >> >> Here's /var/log/messages for an attempt to upgrade the iDRAC from running >> 'dsu' onwards: >> >> Nov 4 13:22:37 server1 yum[228855]: Erased: >> dsucatalog-20.10.01-3DT6M.noarch Nov 4 13:22:43 server1 yum[228881]: >> Installed: dsucatalog-20.10.01-3DT6M.noarch Nov 4 13:23:15 server1 >> kernel: usb 1-14.1.2: new high-speed USB device number 32 using >> xhci_hcd Nov 4 13:23:15 server1 kernel: usb 1-14.1.2: New USB device >> found, idVendor=0624, idProduct=0250, bcdDevice= 0.00 Nov 4 13:23:15 >> server1 kernel: usb 1-14.1.2: New USB device strings: Mfr=4, >> Product=5, SerialNumber=6 Nov 4 13:23:15 server1 kernel: usb >> 1-14.1.2: Product: Mass Storage Function Nov 4 13:23:15 server1 >> kernel: usb 1-14.1.2: Manufacturer: Avocent Nov 4 13:23:15 server1 kernel: >> usb 1-14.1.2: SerialNumber: 20180726-0 Nov 4 13:23:15 server1 kernel: >> usb-storage 1-14.1.2:1.0: USB Mass Storage device detected Nov 4 13:23:15 >> server1 kernel: scsi host34: usb-storage 1-14.1.2:1.0 >> Nov 4 13:23:16 server1 kernel: scsi 34:0:0:0: Direct-Access Linux >> SECUPD 0399 PQ: 0 ANSI: 0 CCS >> Nov 4 13:23:16 server1 kernel: sd 34:0:0:0: Attached scsi generic >> sg27 type 0 Nov 4 13:23:16 server1 kernel: sd 34:0:0:0: Power-on or >> device reset occurred Nov 4 13:23:16 server1 kernel: sd 34:0:0:0: >> [sdab] 2112 512-byte logical blocks: (1.08 MB/1.03 MiB) Nov 4 >> 13:23:16 server1 kernel: sd 34:0:0:0: [sdab] Write Protect is off Nov >> 4 13:23:17 server1 kernel: sd 34:0:0:0: [sdab] No Caching mode page >> found Nov 4 13:23:17 server1 kernel: sd 34:0:0:0: [sdab] Assuming drive >> cache: write through Nov 4 13:23:17 server1 kernel: sdab: >> Nov 4 13:23:17 server1 kernel: sd 34:0:0:0: [sdab] Attached SCSI >> removable disk Nov 4 13:23:17 server1 multipathd: sdab: add path >> (uevent) Nov 4 13:23:32 server1 kernel: usb 1-14.1.2: USB >> disconnect, device number 32 Nov 4 13:23:32 server1 multipathd: >> sdab: remove path (uevent) Nov 4 13:23:32 server1 multipathd: sdab: >> path already removed Nov 4 13:23:36 server1 kernel: usb 1-14.1.2: >> new high-speed USB device number 33 using xhci_hcd Nov 4 13:23:36 >> server1 kernel: usb 1-14.1.2: New USB device found, idVendor=0624, >> idProduct=0250, bcdDevice= 0.00 Nov 4 13:23:36 server1 kernel: usb >> 1-14.1.2: New USB device strings: Mfr=4, Product=5, SerialNumber=6 >> Nov 4 13:23:36 server1 kernel: usb 1-14.1.2: Product: Mass Storage >> Function Nov 4 13:23:36 server1 kernel: usb 1-14.1.2: Manufacturer: >> Avocent Nov 4 13:23:36 server1 kernel: usb 1-14.1.2: SerialNumber: >> 20180726-0 Nov 4 13:23:36 server1 kernel: usb-storage 1-14.1.2:1.0: USB >> Mass Storage device detected Nov 4 13:23:36 server1 kernel: scsi host35: >> usb-storage 1-14.1.2:1.0 >> Nov 4 13:23:37 server1 kernel: scsi 35:0:0:0: Direct-Access Linux >> SECUPD 0399 PQ: 0 ANSI: 0 CCS >> Nov 4 13:23:37 server1 kernel: sd 35:0:0:0: Attached scsi generic >> sg27 type 0 Nov 4 13:23:37 server1 kernel: sd 35:0:0:0: Power-on or >> device reset occurred Nov 4 13:23:37 server1 kernel: sd 35:0:0:0: >> [sdab] 2112 512-byte logical blocks: (1.08 MB/1.03 MiB) Nov 4 >> 13:23:37 server1 kernel: sd 35:0:0:0: [sdab] Write Protect is off Nov >> 4 13:23:37 server1 kernel: sd 35:0:0:0: [sdab] No Caching mode page >> found Nov 4 13:23:37 server1 kernel: sd 35:0:0:0: [sdab] Assuming drive >> cache: write through Nov 4 13:23:38 server1 kernel: sdab: >> Nov 4 13:23:38 server1 kernel: sd 35:0:0:0: [sdab] Attached SCSI >> removable disk Nov 4 13:23:38 server1 multipathd: sdab: add path >> (uevent) Nov 4 13:23:52 server1 kernel: usb 1-14.1.2: USB >> disconnect, device number 33 Nov 4 13:23:52 server1 multipathd: >> sdab: remove path (uevent) Nov 4 13:23:52 server1 multipathd: sdab: >> path already removed Nov 4 13:24:32 server1 yum[249182]: Erased: >> iDRAC-with-Lifecycle-Controller_Firmware_FP2XW_LN_4.22.00.53_A00-4.22 >> .00.53-20.10.01.noarch Nov 4 13:24:59 server1 yum[249651]: >> Installed: >> iDRAC-with-Lifecycle-Controller_Firmware_FP2XW_LN_4.22.00.53_A00-4.22 >> .00.53-20.10.01.noarch Nov 4 13:25:26 server1 kernel: usb 1-14.1.2: >> new high-speed USB device number 34 using xhci_hcd Nov 4 13:25:26 >> server1 kernel: usb 1-14.1.2: New USB device found, idVendor=0624, >> idProduct=0250, bcdDevice= 0.00 Nov 4 13:25:26 server1 kernel: usb >> 1-14.1.2: New USB device strings: Mfr=4, Product=5, SerialNumber=6 >> Nov 4 13:25:26 server1 kernel: usb 1-14.1.2: Product: Mass Storage >> Function Nov 4 13:25:26 server1 kernel: usb 1-14.1.2: Manufacturer: >> Avocent Nov 4 13:25:26 server1 kernel: usb 1-14.1.2: SerialNumber: >> 20180726-0 Nov 4 13:25:26 server1 kernel: usb-storage 1-14.1.2:1.0: USB >> Mass Storage device detected Nov 4 13:25:26 server1 kernel: scsi host36: >> usb-storage 1-14.1.2:1.0 >> Nov 4 13:25:27 server1 kernel: scsi 36:0:0:0: Direct-Access Linux >> scrtch 0399 PQ: 0 ANSI: 0 CCS >> Nov 4 13:25:27 server1 kernel: sd 36:0:0:0: Attached scsi generic >> sg27 type 0 Nov 4 13:25:27 server1 kernel: sd 36:0:0:0: Power-on or >> device reset occurred Nov 4 13:25:27 server1 kernel: sd 36:0:0:0: >> [sdab] 630784 512-byte logical blocks: (322 MB/308 MiB) Nov 4 >> 13:25:27 server1 kernel: sd 36:0:0:0: [sdab] Write Protect is off Nov >> 4 13:25:27 server1 kernel: sd 36:0:0:0: [sdab] No Caching mode page >> found Nov 4 13:25:27 server1 kernel: sd 36:0:0:0: [sdab] Assuming drive >> cache: write through Nov 4 13:25:28 server1 kernel: sdab: >> Nov 4 13:25:28 server1 kernel: sd 36:0:0:0: [sdab] Attached SCSI >> removable disk Nov 4 13:25:28 server1 multipathd: sdab: add path >> (uevent) Nov 4 13:25:28 server1 multipathd: mpathek: load table [0 >> 630784 multipath 1 queue_if_no_path 0 1 1 service-time 0 1 1 65:176 >> 1] Nov 4 13:25:28 server1 multipathd: mpathek: event checker started >> Nov 4 13:25:28 server1 multipathd: sdab [65:176]: path added to >> devmap mpathek Nov 4 13:26:30 server1 kernel: usb 1-14.1.2: USB >> disconnect, device number 34 Nov 4 13:26:30 server1 multipathd: >> sdab: remove path (uevent) Nov 4 13:26:30 server1 multipathd: >> mpathek: devmap removed Nov 4 13:26:30 server1 multipathd: mpathek: >> stop event checker thread (140177298130688) Nov 4 13:26:30 server1 >> multipathd: mpathek: removed map after removing all paths Nov 4 >> 13:26:30 server1 multipathd: dm-28: remove map (uevent) Nov 4 >> 13:26:30 server1 multipathd: dm-28: devmap not registered, can't >> remove Nov 4 13:26:30 server1 multipathd: dm-28: remove map (uevent) >> Nov 4 13:26:36 server1 kernel: usb 1-14.1.2: new high-speed USB >> device number 35 using xhci_hcd Nov 4 13:26:37 server1 kernel: usb >> 1-14.1.2: New USB device found, idVendor=0624, idProduct=0250, >> bcdDevice= 0.00 Nov 4 13:26:37 server1 kernel: usb 1-14.1.2: New USB >> device strings: Mfr=4, Product=5, SerialNumber=6 Nov 4 13:26:37 >> server1 kernel: usb 1-14.1.2: Product: Mass Storage Function Nov 4 13:26:37 >> server1 kernel: usb 1-14.1.2: Manufacturer: Avocent Nov 4 13:26:37 server1 >> kernel: usb 1-14.1.2: SerialNumber: 20180726-0 Nov 4 13:26:37 server1 >> kernel: usb-storage 1-14.1.2:1.0: USB Mass Storage device detected Nov 4 >> 13:26:37 server1 kernel: scsi host37: usb-storage 1-14.1.2:1.0 >> Nov 4 13:26:38 server1 kernel: scsi 37:0:0:0: Direct-Access Linux >> scrtch 0399 PQ: 0 ANSI: 0 CCS >> Nov 4 13:26:38 server1 kernel: sd 37:0:0:0: Attached scsi generic >> sg27 type 0 Nov 4 13:26:38 server1 kernel: sd 37:0:0:0: Power-on or >> device reset occurred Nov 4 13:26:38 server1 kernel: sd 37:0:0:0: >> [sdab] 630784 512-byte logical blocks: (322 MB/308 MiB) Nov 4 >> 13:26:38 server1 kernel: sd 37:0:0:0: [sdab] Write Protect is off Nov >> 4 13:26:38 server1 kernel: sd 37:0:0:0: [sdab] No Caching mode page >> found Nov 4 13:26:38 server1 kernel: sd 37:0:0:0: [sdab] Assuming drive >> cache: write through Nov 4 13:26:38 server1 kernel: sdab: >> Nov 4 13:26:38 server1 kernel: sd 37:0:0:0: [sdab] Attached SCSI >> removable disk Nov 4 13:26:38 server1 multipathd: sdab: add path >> (uevent) Nov 4 13:26:39 server1 multipathd: mpathek: load table [0 >> 630784 multipath 1 queue_if_no_path 0 1 1 service-time 0 1 1 65:176 >> 1] Nov 4 13:26:39 server1 multipathd: mpathek: event checker started >> Nov 4 13:26:39 server1 multipathd: sdab [65:176]: path added to >> devmap mpathek Nov 4 13:27:40 server1 kernel: usb 1-14.1.2: USB >> disconnect, device number 35 Nov 4 13:27:40 server1 multipathd: >> sdab: remove path (uevent) Nov 4 13:27:40 server1 multipathd: >> mpathek: devmap removed Nov 4 13:27:40 server1 multipathd: mpathek: >> stop event checker thread (140177298130688) Nov 4 13:27:40 server1 >> multipathd: mpathek: removed map after removing all paths Nov 4 >> 13:27:40 server1 multipathd: dm-28: remove map (uevent) Nov 4 >> 13:27:40 server1 multipathd: dm-28: devmap not registered, can't >> remove Nov 4 13:27:40 server1 multipathd: dm-28: remove map (uevent) >> Nov 4 13:27:47 server1 kernel: usb 1-14.1.2: new high-speed USB >> device number 36 using xhci_hcd Nov 4 13:27:47 server1 kernel: usb >> 1-14.1.2: New USB device found, idVendor=0624, idProduct=0250, >> bcdDevice= 0.00 Nov 4 13:27:47 server1 kernel: usb 1-14.1.2: New USB >> device strings: Mfr=4, Product=5, SerialNumber=6 Nov 4 13:27:47 >> server1 kernel: usb 1-14.1.2: Product: Mass Storage Function Nov 4 13:27:47 >> server1 kernel: usb 1-14.1.2: Manufacturer: Avocent Nov 4 13:27:47 server1 >> kernel: usb 1-14.1.2: SerialNumber: 20180726-0 Nov 4 13:27:47 server1 >> kernel: usb-storage 1-14.1.2:1.0: USB Mass Storage device detected Nov 4 >> 13:27:47 server1 kernel: scsi host38: usb-storage 1-14.1.2:1.0 >> Nov 4 13:27:48 server1 kernel: scsi 38:0:0:0: Direct-Access Linux >> scrtch 0399 PQ: 0 ANSI: 0 CCS >> Nov 4 13:27:48 server1 kernel: sd 38:0:0:0: Attached scsi generic >> sg27 type 0 Nov 4 13:27:48 server1 kernel: sd 38:0:0:0: Power-on or >> device reset occurred Nov 4 13:27:48 server1 kernel: sd 38:0:0:0: >> [sdab] 630784 512-byte logical blocks: (322 MB/308 MiB) Nov 4 >> 13:27:48 server1 kernel: sd 38:0:0:0: [sdab] Write Protect is off Nov >> 4 13:27:48 server1 kernel: sd 38:0:0:0: [sdab] No Caching mode page >> found Nov 4 13:27:48 server1 kernel: sd 38:0:0:0: [sdab] Assuming drive >> cache: write through Nov 4 13:27:48 server1 kernel: sdab: >> Nov 4 13:27:48 server1 kernel: sd 38:0:0:0: [sdab] Attached SCSI >> removable disk Nov 4 13:27:49 server1 multipathd: sdab: add path >> (uevent) Nov 4 13:27:49 server1 multipathd: mpathek: load table [0 >> 630784 multipath 1 queue_if_no_path 0 1 1 service-time 0 1 1 65:176 >> 1] Nov 4 13:27:49 server1 multipathd: mpathek: event checker started >> Nov 4 13:27:49 server1 multipathd: sdab [65:176]: path added to >> devmap mpathek Nov 4 13:28:51 server1 kernel: usb 1-14.1.2: USB >> disconnect, device number 36 Nov 4 13:28:51 server1 multipathd: >> sdab: remove path (uevent) Nov 4 13:28:51 server1 multipathd: >> mpathek: devmap removed Nov 4 13:28:51 server1 multipathd: mpathek: >> stop event checker thread (140177298130688) Nov 4 13:28:51 server1 >> multipathd: mpathek: removed map after removing all paths Nov 4 >> 13:28:51 server1 multipathd: dm-28: remove map (uevent) Nov 4 >> 13:28:51 server1 multipathd: dm-28: devmap not registered, can't >> remove Nov 4 13:28:51 server1 multipathd: dm-28: remove map (uevent) >> Nov 4 13:28:54 server1 spsetup.sh: Package Release ID=FP2XWA00 >> Package Description=iDRAC with Lifecycle Controller 4.22.00.53, A00 >> Exit code = 0 (Success) Nov 4 13:28:54 server1 root: Update Package: >> iDRAC with Lifecycle Controller Firmware: Exit code = 0 (Success) >> Support Log >> path=/var/log/dell/updatepackage/log/support/iDRAC-with-Lifecycle-Con >> troller_Firmware_FP2XW_LN_4.22.00.53_A00.log >> >> This was a failed attempt. >> >> So it looks like you've added ANOTHER vendor/product variant of >> "Linux/scrtch" to an ever-increasing list. Why do you keep doing this? >> I've added the below stanza to my /etc/multipath.conf blacklist section: >> >> device { >> vendor "Linux" >> product "scrtch" >> } >> >> and on re-running 'dsu' the iDRAC update has succeeded. >> >> PLEASE, Dell, stick to one set of vendor/product strings! I'd appreciate >> having a reply that says more than "glad it's working" to explain >> Engineering's thinking behind changing the vendor/product string, again. >> >> Ben >> >> -----Original Message----- >> From: Gore, Santosh <[email protected]> >> Sent: 04 November 2020 04:46 >> To: Ben Argyle <[email protected]>; [email protected] >> Subject: RE: [Linux-PowerEdge] iDRAC update failure >> >> Hi >> >> As part of iDRAC update, the USB drive is exposed from iDRAC to host >> OS to transfer payload. Please make sure the USB device is not >> blacklisted on your system and could you please share the OS logs ( >> /var/log/messages) after iDRAC update >> >> Thanks >> Santosh >> >> -----Original Message----- >> From: Linux-PowerEdge <[email protected]> On Behalf Of >> Ben Argyle >> Sent: Tuesday, November 3, 2020 9:53 PM >> To: [email protected] >> Subject: Re: [Linux-PowerEdge] iDRAC update failure >> >> >> [EXTERNAL EMAIL] >> >> Yes. I did a soft reset from the iDRAC web GUI >> (Maintenance->Diagnostics->Reset iDRAC). I don't want to do a >> hard/configuration reset and lose IP details, etc. Still no effect: >> >> =================> Update Package application started <============= >> >> Command: >> /var/log/dell/updatepackage/log/support/iDRAC-with-Lifecycle-Controll >> er_Firmware_FP2XW_LN_4.22.00.53_A00.BIN >> -f -q >> >> Date: Tue 3 Nov 16:14:58 GMT 2020 >> >> ===================================================================== >> ==== >> >> Release ID: FP2XWA00 >> >> Update Package version: 20.06.200 (BLD_888) >> >> Collecting inventory... >> <?xml version="1.0"?> >> <SVMInventory lang="en"> >> <Device componentID="25227" display=" iDRAC"> >> <Application componentType="FRMW" version="4.00.00.00" display=" >> iDRAC"/> >> </Device> >> <System systemID="716"/> >> <OperatingSystem osVendor="Red Hat" osArch="x64" majorVersion="7.0" >> minorVersion="9" spMajorVersion="0" spMinorVersion="0"/> >> <Device componentID="159" display="BIOS" impactsTPMmeasurements="TRUE"> >> <Display>BIOS</Display> >> <Application componentType="BIOS" version="2.8.2" display="BIOS"/> >> </Device> >> </SVMInventory> >> Creating payload file list for UpdRollBack by framework, if needed later. >> MovePayload: Entry >> MovePayload: Processing payload directory. >> MovePayload: Moving firmimgFIT.d9 >> MovePayload: Exiting. >> Running validation... >> >> iDRAC >> Application: iDRAC >> Previous version: 4.00.00.00 >> New version: 4.22.00.53 >> >> The version of this Update Package is newer than the currently installed >> version. >> Software application name: iDRAC >> Package version: 4.22.00.53 >> Installed version: 4.00.00.00 >> >> >> Executing update... >> WARNING: DO NOT STOP THIS PROCESS OR INSTALL OTHER PRODUCTS WHILE UPDATE IS >> IN PROGRESS. >> THESE ACTIONS MAY CAUSE YOUR SYSTEM TO BECOME UNSTABLE! >> Atleast one device updated: Check return 255 >> Device: iDRAC >> Application: iDRAC >> Failed to reach virtual device. This could be caused by BitLocker or >> other security software being enabled. For more information, see the Update >> Package User's Guide. >> >> ============================> Update Result >> <============================ >> >> Update complete >> Application: iDRAC >> Previous version: 4.00.00.00 >> New version: 4.22.00.53 >> ===================================================================== >> ==== >> Exit code = 0 (Success) >> Tue 3 Nov 16:18:36 GMT 2020 >> >> >> Ben >> >> -----Original Message----- >> From: Linux-PowerEdge <[email protected]> On Behalf Of >> Patrick Boutilier >> Sent: 03 November 2020 13:57 >> To: [email protected] >> Subject: Re: [Linux-PowerEdge] iDRAC update failure >> >> >> [EXTERNAL EMAIL] >> >> Have you tried resetting the iDRAC? >> >> https://www.dell.com/support/article/en-ca/sln305793/how-to-reset-the >> -internal-dell-remote-access-controller-idrac-on-a-poweredge-server?l >> ang=en >> >> >> >> On 11/3/20 3:50 AM, Ben Argyle wrote: >>> [EXTERNAL EMAIL] >>> >>> Hi All, >>> >>> I'm seeing the below in >>> /var/log/dell/updatepackage/log/support/iDRAC-with-Lifecycle-Controller_Firmware_FP2XW_LN_4.22.00.53_A00.log >>> when attempting to upgrade the IDRAC from 4.00.00.00 to 4.22.00.53 with >>> 'dsu'. I thought it was due to having too low a version of the BIOS >>> (2.4.8), so successfully upgraded that to 2.8.2 and tried again. There was >>> no change to the logged output other than it registering the newer BIOS >>> version. I'm _not_ running BitLocker, or anything other than fairly >>> standard software outside of the OS-supplied (which I hadn't started up >>> anyway). >>> >>> Every other server of this type (R640) has been fine. Thoughts? >>> >>> Ben >>> >>> =================> Update Package application started <============= >>> >>> Command: >>> /scripts/iDRAC-with-Lifecycle-Controller_Firmware_FP2XW_LN_4.22.00.53_A00.BIN >>> -f -q >>> >>> Date: Tue 3 Nov 07:38:04 GMT 2020 >>> >>> ==================================================================== >>> == >>> === >>> >>> Release ID: FP2XWA00 >>> >>> Update Package version: 20.06.200 (BLD_888) >>> >>> Collecting inventory... >>> <?xml version="1.0"?> >>> <SVMInventory lang="en"> >>> <Device componentID="25227" display=" iDRAC"> >>> <Application componentType="FRMW" version="4.00.00.00" display=" >>> iDRAC"/> >>> </Device> >>> <System systemID="716"/> >>> <OperatingSystem osVendor="Red Hat" osArch="x64" majorVersion="7.0" >>> minorVersion="9" spMajorVersion="0" spMinorVersion="0"/> >>> <Device componentID="159" display="BIOS" impactsTPMmeasurements="TRUE"> >>> <Display>BIOS</Display> >>> <Application componentType="BIOS" version="2.8.2" display="BIOS"/> >>> </Device> >>> </SVMInventory> >>> Creating payload file list for UpdRollBack by framework, if needed later. >>> MovePayload: Entry >>> MovePayload: Processing payload directory. >>> MovePayload: Moving firmimgFIT.d9 >>> MovePayload: Exiting. >>> Running validation... >>> >>> iDRAC >>> Application: iDRAC >>> Previous version: 4.00.00.00 >>> New version: 4.22.00.53 >>> >>> The version of this Update Package is newer than the currently installed >>> version. >>> Software application name: iDRAC >>> Package version: 4.22.00.53 >>> Installed version: 4.00.00.00 >>> >>> >>> Executing update... >>> WARNING: DO NOT STOP THIS PROCESS OR INSTALL OTHER PRODUCTS WHILE >>> UPDATE IS IN PROGRESS. >>> THESE ACTIONS MAY CAUSE YOUR SYSTEM TO BECOME UNSTABLE! >>> Atleast one device updated: Check return 255 >>> Device: iDRAC >>> Application: iDRAC >>> Failed to reach virtual device. This could be caused by BitLocker or >>> other security software being enabled. For more information, see the Update >>> Package User's Guide. >>> >>> ============================> Update Result >>> <============================ >>> >>> Update complete >>> Application: iDRAC >>> Previous version: 4.00.00.00 >>> New version: 4.22.00.53 >>> ==================================================================== >>> == >>> === >>> Exit code = 0 (Success) >>> Tue 3 Nov 07:41:43 GMT 2020 >>> >>> _______________________________________________ >>> Linux-PowerEdge mailing list >>> [email protected] >>> https://lists.us.dell.com/mailman/listinfo/linux-poweredge >>> >> _______________________________________________ >> Linux-PowerEdge mailing list >> [email protected] >> https://lists.us.dell.com/mailman/listinfo/linux-poweredge >> >> _______________________________________________ >> Linux-PowerEdge mailing list >> [email protected] >> https://lists.us.dell.com/mailman/listinfo/linux-poweredge >> >> _______________________________________________ >> Linux-PowerEdge mailing list >> [email protected] >> https://lists.us.dell.com/mailman/listinfo/linux-poweredge > _______________________________________________ > Linux-PowerEdge mailing list > [email protected] > https://lists.us.dell.com/mailman/listinfo/linux-poweredge _______________________________________________ Linux-PowerEdge mailing list [email protected] https://lists.us.dell.com/mailman/listinfo/linux-poweredge _______________________________________________ Linux-PowerEdge mailing list [email protected] https://lists.us.dell.com/mailman/listinfo/linux-poweredge