hi, unknown of you particular FW versions for 11G servers a proven sequence is
1. iDRAC FW via iDRAC GUI 2. LCC repair package via IDRAC GUI 3. BIOS update using method of your choice 4. if necessary LCC FW using method of your choice (repair package is not always most recent) 5. update drivers if required 6. all other FWs ________________________________ From: linux-poweredge-bounces-Lists on behalf of Ricardo Stella <[email protected]> Sent: Friday, May 12, 2017 6:38 PM To: linux-poweredge-Lists Subject: [Linux-PowerEdge] Firmware upgrade method Hi, while I still try to recover these R610 from a failed firmware upgrade, I got a hold of an R710 which has RHEL 6.9 installed (just updated) but firmware is very much old. Is there a preferred update method and or steps? I would do it via DSU, but should I update something first before anything else? Box has iDRAC 6 enterprise, and Perc H700. Thanks in advance. Ricardo. -- °(((=((===°°°(((================================================
_______________________________________________ Linux-PowerEdge mailing list [email protected] https://lists.us.dell.com/mailman/listinfo/linux-poweredge