hi, unknown of you particular FW versions for 11G servers a proven sequence is

1. iDRAC FW via iDRAC GUI

2. LCC repair package via IDRAC GUI

3. BIOS update using method of your choice

4. if necessary LCC FW using method of your choice (repair package is not 
always most recent)

5. update drivers if required

6. all other FWs



________________________________
From: linux-poweredge-bounces-Lists on behalf of Ricardo Stella 
<[email protected]>
Sent: Friday, May 12, 2017 6:38 PM
To: linux-poweredge-Lists
Subject: [Linux-PowerEdge] Firmware upgrade method


Hi,

while I still try to recover these R610 from a failed firmware upgrade, I got a 
hold of an R710 which has RHEL 6.9 installed (just updated) but firmware is 
very much old.

Is there a preferred update method and or steps? I would do it via DSU, but 
should I update something first before anything else? Box has iDRAC 6 
enterprise, and Perc H700.

Thanks in advance.

Ricardo.

--
°(((=((===°°°(((================================================
_______________________________________________
Linux-PowerEdge mailing list
[email protected]
https://lists.us.dell.com/mailman/listinfo/linux-poweredge