On Mon, Mar 16, 2026 at 07:19:45PM +0200, Erikas Bitovtas wrote: > These sensors can accept 2 supplies - one for the sensor and one for IR > LED [1]. Add supply properties for the sensor - 2 for the sensors and > one external, for their I2C bus, to ensure the sensor is powered on > before proceeding with setup. > > [1] https://www.vishay.com/docs/84274/vcnl4040.pdf > > Reviewed-by: David Lechner <[email protected]> > Signed-off-by: Erikas Bitovtas <[email protected]> > --- > Documentation/devicetree/bindings/iio/light/vishay,vcnl4000.yaml | 7 +++++++ > 1 file changed, 7 insertions(+) > > diff --git a/Documentation/devicetree/bindings/iio/light/vishay,vcnl4000.yaml > b/Documentation/devicetree/bindings/iio/light/vishay,vcnl4000.yaml > index 2ba4d5de4ec4..a1b4c02db246 100644 > --- a/Documentation/devicetree/bindings/iio/light/vishay,vcnl4000.yaml > +++ b/Documentation/devicetree/bindings/iio/light/vishay,vcnl4000.yaml > @@ -33,6 +33,10 @@ properties: > interrupts: > maxItems: 1 > > + vdd-supply: true > + vddio-supply: true > + vled-supply: true
Same comments as before, I do not see improvements. Best regards, Krzysztof