On Sat, Jul 23, 2016 at 02:34:08AM +0800, [email protected] wrote:
> From: Tom Yan <[email protected]>
> 
> ata_mselect_*() would initialize a char array for storing a copy of
> the current mode page. However, char could be signed char. In that
> case, bytes larger than 127 would be converted to negative number.
> 
> For example, 0xff from def_control_mpage[] would become -1. This
> prevented ata_mselect_control() from working at all, since when it
> did the read-only bits check, there would always be a mismatch.
> 
> Signed-off-by: Tom Yan <[email protected]>

Applied to libata/for-4.9.

Thanks.

-- 
tejun