The RNGB block on 6ull has no major differences, but it has no
switchable clock.

Signed-off-by: Christian Eggers <cegg...@arri.de>
---
 arch/arm/boot/dts/imx6ull.dtsi | 6 ++++++
 1 file changed, 6 insertions(+)

diff --git a/arch/arm/boot/dts/imx6ull.dtsi b/arch/arm/boot/dts/imx6ull.dtsi
index fcde7f77ae42..3d021b304a83 100644
--- a/arch/arm/boot/dts/imx6ull.dtsi
+++ b/arch/arm/boot/dts/imx6ull.dtsi
@@ -68,6 +68,12 @@ dcp: crypto@2280000 {
                                clock-names = "dcp";
                        };
 
+                       rngb: rng@2284000 {
+                               compatible = "fsl,imx6ull-dcp", 
"fsl,imx25-rngb";
+                               reg = <0x02284000 0x4000>;
+                               interrupts = <GIC_SPI 6 IRQ_TYPE_LEVEL_HIGH>;
+                       };
+
                        iomuxc_snvs: iomuxc-snvs@2290000 {
                                compatible = "fsl,imx6ull-iomuxc-snvs";
                                reg = <0x02290000 0x4000>;
-- 
Christian Eggers
Embedded software developer

Arnold & Richter Cine Technik GmbH & Co. Betriebs KG
Sitz: Muenchen - Registergericht: Amtsgericht Muenchen - Handelsregisternummer: 
HRA 57918
Persoenlich haftender Gesellschafter: Arnold & Richter Cine Technik GmbH
Sitz: Muenchen - Registergericht: Amtsgericht Muenchen - Handelsregisternummer: 
HRB 54477
Geschaeftsfuehrer: Dr. Michael Neuhaeuser; Stephan Schenk; Walter Trauninger; 
Markus Zeiler