Hi,

I'm doing my first steps in lens calibration. Currently I'm trying to
get distortion correction data from Hugin. 

What I've noticed is that working with different images I get different
values for a, b, c. As Hugin seems to average all values for individual
focus lengths (???) I did not keep track of the values, only noticed the
change.

Example values:

a; b;c; computed using 4 images:

0,032214; -0,105173; 0,069074

computed using only one of the images:

0,031828; -0,100712; 0,058477

Is this normal or an indication of bad images used for calibration?

Is there a simple way to test (aka see in action) the computed values? I
tried it through Gimp + GimpLensfun, but my
entry ./local/share/lensfun/test.xml doesn't get included in the lens
list. The file itself gets loaded - I get an error message, when it
contains garbage (but only if before <lensdatabase>).

TIA,
Oliver



------------------------------------------------------------------------------