Adrien Grand created LUCENE-9529: ------------------------------------ Summary: Larger stored fields block sizes mean we're more likely to disable optimized bulk merging Key: LUCENE-9529 URL: https://issues.apache.org/jira/browse/LUCENE-9529 Project: Lucene - Core Issue Type: Improvement Reporter: Adrien Grand
Whenever possible when merging stored fields, Lucene tries to copy the compressed data instead of decompressing the source segment to then re-compressing in the destination segment. A problem with this approach is that if some blocks are incomplete (typically the last block of a segment) then it remains incomplete in the destination segment too, and if we do it for too long we end up with a bad compression ratio. So Lucene keeps track of these incomplete blocks, and makes sure to keep a ratio of incomplete blocks below 1%. But as we increased the block size, it has become more likely to have a high ratio of incomplete blocks. E.g. if you have a segment with 1MB of stored fields, with 16kB blocks like before, you have 63 complete blocks and 1 incomplete block, or 1.6%. But now with ~512kB blocks, you have one complete block and 1 incomplete block, ie. 50%. I'm not sure how to fix it or even whether it should be fixed but wanted to open an issue to track this. -- This message was sent by Atlassian Jira (v8.3.4#803005) --------------------------------------------------------------------- To unsubscribe, e-mail: issues-unsubscr...@lucene.apache.org For additional commands, e-mail: issues-h...@lucene.apache.org