Ian Lance Taylor wrote:
Boris Boesler <[EMAIL PROTECTED]> writes:
The following code generators use FOR_EACH_BB[_REVERSE] in the
target machine dependent reorg pass:
- bfin
- frv
- ia64
- mt
- s390
Are these invalid code generators then? Or are we talking about
different things?
Yes, they are probably broken.
Not if they call compute_bb_for_insn at the start of their reorg pass.
Bernd
--
This footer brought to you by insane German lawmakers.
Analog Devices GmbH Wilhelm-Wagenfeld-Str. 6 80807 Muenchen
Sitz der Gesellschaft Muenchen, Registergericht Muenchen HRB 40368
Geschaeftsfuehrer Thomas Wessel, William A. Martin, Margaret Seif