VTA can't get correct in Zynq Ultra Scale based device. We once thought this
was a coherency problem, but recently I found there may be a bug in HLS C VTA
hardware with my partner
@hht.
Only FINISH instruction can set VTA_COMPUTE_DONE register in compute module.
And only GEMM/ALU instruction will reset VTA_COMPUTE_DONE register, while
LOAD/STORE can't.
The last instruction in instruction queue is FINISH. The processor queries
VTA_COMPUTE_DONE register to confirm that the VTA compute is complete. But
VTA_COMPUTE_DONE remains set until VTA runs again and excutes a GEMM/ALU
instruction. If processor queries the register before VTA excutes a GEMM/ALU
instruction, it will misunderstand that the VTA compute is completed.
I modified the source code of compute module IP to make VTA_COMPUTE_DONE
register clear on read.
```plain
reg [1:0] rise_done_buf;
always @(posedge ACLK) begin
if(ARESET)
rise_done_buf <= 2'b0;
else if (ACLK_EN) begin
rise_done_buf[0] <= done_o[0];
rise_done_buf[1] <= rise_done_buf[0];
end
end
wire rise_done = rise_done_buf[0] & (~rise_done_buf[1]);
reg [31:0] int_done_tmp;
always @(posedge ACLK) begin
if (ARESET)
int_done_tmp <= 32'b0;
else if (ACLK_EN) begin
if (rise_done)
int_done_tmp <= 32'b1;
else if (ar_hs && raddr == ADDR_DONE_O_DATA_0)
int_done_tmp <= 32'b0; // clear on read
end
end
```
After modifying, I get correct results on ZCU104 platform.