Package: apcupsd
Version: 3.14.8-2
Severity: minor

Hi,

during system shutdown, ups-monitor gets calles from /etc/init.de/halt, and
calls apccontrol killpower.

In apccontrol, most stuff gets piped to /usr/bin/wall, but at the time it is
called, /usr might already have been unmounted, which yields an error message
prior to power off (it's only the error msg, the apccontrol call is executed
anyway.).

The fix is quite simple, remove the |$(WALL) from the killpower call in
apccontrol.

regards,
        Dietz

-- System Information:
Debian Release: 6.0.7
  APT prefers oldstable
  APT policy: (500, 'oldstable')
Architecture: i386 (i686)

Kernel: Linux 2.6.39.4 (SMP w/2 CPU cores)
Locale: LANG=C, LC_CTYPE=C (charmap=ANSI_X3.4-1968)
Shell: /bin/sh linked to /bin/bash

Versions of packages apcupsd depends on:
ii  libc6                         2.11.3-4   Embedded GNU C Library: Shared lib
ii  libgcc1                       1:4.4.5-8  GCC support library
ii  libwrap0                      7.6.q-19   Wietse Venema's TCP wrappers libra

Versions of packages apcupsd recommends:
ii  apcupsd-doc                   3.14.8-2   APC UPS Power Management (document

Versions of packages apcupsd suggests:
ii  apcupsd-cgi                   3.14.8-2   APC UPS Power Management (web inte
pn  hal                           <none>     (no description available)
ii  udev                          164-3      /dev/ and hotplug management daemo

-- Configuration Files:
/etc/apcupsd/apcupsd.conf changed [not included]