> I have a small system based on one TDM400 card with > - 2 FXO modules for incoming lines > - 1 FXS module for one phone > > The system was working fine in the past. The motherboard was exchanged > and during the switch, the phones line was rewired with a mistake and a > incoming phone line was connected to the FXS module, and there was > ringing voltage on the module. > > Now, the system kinda works but the FXS module stays in state Rsrvd, no > ringing, all the call goes directly to voice-mail (it's programmed this > way in extensions.conf), no dial-tone on the phone. > > Is my FXS module dead ?
> Freshmaker passed register test > Module 0: Installed -- AUTO FXO (FCC mode) > Module 1: Installed -- AUTO FXO (FCC mode) > Module 2: Installed -- AUTO FXS/DPO > Module 3: Not installed > Power alarm on module 3, resetting! That would be my guess. Looking at the specs for the Silicon Labs chips used on the modules, I would have guessed the module would have been protected from ringing voltage. But, who knows for sure. Might try calling digium support to see what they think. _______________________________________________ Asterisk-Users mailing list [EMAIL PROTECTED] http://lists.digium.com/mailman/listinfo/asterisk-users To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users