On Thu, 2004-07-08 at 04:28, Mikael Magnusson wrote: > On Thu, Jul 08, 2004 at 08:30:59PM +1200, Richard Scobie wrote: > > > > One thing to watch for here is RX gain if busydetect does not seem to be > > working after trying all the combinations. > > > > I had a 2 x X101P setup which busydetected perfectly - TX and RX gains > > were at the default levels. > > > > The X101Ps were replaced by a TDM card with 4 x FXO modules and with no > > config changes, busydetect stopped working. After incrementing in 1dB > > steps, an RX gain of 3.0 brought back reliable busydetect. > > > > I look forward to Rich Adamsons forthcoming writeup on setting up the > > gain distribution in an Asterisk system, to get everything working > > optimally. > > > > In Sweden we don't get a busy signal when the remote part hangs up. > Instead remote hang up is signaled by reversing the polarity of the line. > Can X100P/X101P detect polarity reversal when off hook, on hook, or both?
I believe the chip is capable of that detection. It may need a driver tweak to get it there and into a meaningful message in zap. -- Steven Critchfield <[EMAIL PROTECTED]> _______________________________________________ Asterisk-Users mailing list [EMAIL PROTECTED] http://lists.digium.com/mailman/listinfo/asterisk-users To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users