we are connected to netia in warsaw and it works perfect. what you write reminds me of some tests we did with siemens ESWD and it was a nightmare with it. not only CRC4 but wrong line restarts etc ...
Netia uses 5ESS switches and is till now absolutely trouble free :) On Monday 02 June 2003 2:15 pm, Konrad Gorski wrote: > On my side I have no errors too, but on Telco-side are CRC errors. > Are you able to get some stats from the Colt-side? > Konrad > > -----Original Message----- > From: [EMAIL PROTECTED] > [mailto:[EMAIL PROTECTED] On Behalf Of Otmar Lendl > Sent: Monday, June 02, 2003 2:55 PM > To: [EMAIL PROTECTED] > Subject: Re: [Asterisk-Dev] E1, crc-4 errors > > On 2003/06/02 14:06, Konrad Gorski <[EMAIL PROTECTED]> wrote: > > I'v just obtained from Telco results of sync test on line E1<->E100P. > > It's OK, line is synchronized, no errors. Problem is with CRC only. > > Maybe framer on my E100P is faulty (what about, Mark?). > > CRC is essential for certify E100P in Poland. > > > > Is someone in Europe using E100P/E400P connected to E1 with CRC > > checking? > > I connected a E400P to a Colt E1 line in Vienna/Austia last friday. > > My settings are (after lots of googling [like: what driver to use for > that card? Answer: tor2] and guessing): > > span=1,0,0,ccs,hdb3,crc4 > span=2,0,0,ccs,hdb3,crc4 > span=3,0,0,ccs,hdb3,crc4 > span=4,0,0,ccs,hdb3,crc4 > bchan=1-15,17-31 > dchan=16 > bchan=32-46,48-62 > dchan=47 > bchan=63-77,79-93 > dchan=78 > bchan=94-108,110-124 > dchan=109 > > zttool reports: > > x Current Alarms: No alarms. x > x Sync Source: Internally clocked x > x IRQ Misses: 0 x > x Bipolar Viol: 5083 x > x Tx/Rx Levels: 0/ 0 x > x Total/Conf/Act: 31/ 31/ 0 > > > /ol _______________________________________________ Asterisk-Dev mailing list [EMAIL PROTECTED] http://lists.digium.com/mailman/listinfo/asterisk-dev