On 2003/06/02 14:06, Konrad Gorski <[EMAIL PROTECTED]> wrote: > I'v just obtained from Telco results of sync test on line E1<->E100P. > It's OK, line is synchronized, no errors. Problem is with CRC only. > Maybe framer on my E100P is faulty (what about, Mark?). > CRC is essential for certify E100P in Poland. > > Is someone in Europe using E100P/E400P connected to E1 with CRC > checking?
I connected a E400P to a Colt E1 line in Vienna/Austia last friday. My settings are (after lots of googling [like: what driver to use for that card? Answer: tor2] and guessing): span=1,0,0,ccs,hdb3,crc4 span=2,0,0,ccs,hdb3,crc4 span=3,0,0,ccs,hdb3,crc4 span=4,0,0,ccs,hdb3,crc4 bchan=1-15,17-31 dchan=16 bchan=32-46,48-62 dchan=47 bchan=63-77,79-93 dchan=78 bchan=94-108,110-124 dchan=109 zttool reports: x Current Alarms: No alarms. x x Sync Source: Internally clocked x x IRQ Misses: 0 x x Bipolar Viol: 5083 x x Tx/Rx Levels: 0/ 0 x x Total/Conf/Act: 31/ 31/ 0 /ol -- < Otmar Lendl <[EMAIL PROTECTED]> | nic.at Systems Engineer > _______________________________________________ Asterisk-Dev mailing list [EMAIL PROTECTED] http://lists.digium.com/mailman/listinfo/asterisk-dev