Julie, You can use the class manager to add a $\NULL$ menu to the fields, and then use workflow to attach the correct menu. I've done that with the Floor and Room fields. (we are on ARS 7.1 / CMDB 2.1. I assume that hasn't changed for 7.6.04)
As far as getting SynchUI to work, it doesn't work if you have disallowed unqualified searches (again... for our version at least). Enable unqualified searches and see if that helps. Thad On Thu, Aug 9, 2012 at 3:59 PM, Julie Sellers <[email protected]> wrote: > ** > Hi Folks...could use your help! > I need a Char field w/menu attached by workflow on AST:ComputerSystem. > (well actually 4 fields) > The customer is upgrading from v71 to v7604 sp2. > In v71, they just added menus to existing fields like 'Environment > Specification' > I wanted to attach the menus with Change Field actions in an Active Link; > however, > they are not working. (I presume this is because no menu is attached > already.) So... > > Is there any way to avoid modifying the attribute in Class Manager to do > this? > If not, I'll just create new attributes; however, we are having a *DEVIL* > of a time > with SyncUI not working. Have had an open tkt on this w/BMC for the last > several weeks! :( > Suggestions? Thx, js > _attend WWRUG12 www.wwrug.com ARSlist: "Where the Answers Are"_ _______________________________________________________________________________ UNSUBSCRIBE or access ARSlist Archives at www.arslist.org attend wwrug12 www.wwrug12.com ARSList: "Where the Answers Are"