On Wed, 2018-02-28 at 01:19 +0000, Daniel Stone wrote: > From: Louis-Francis Ratté-Boulianne <[email protected]> > > If the Complete event has this mode, the client is not using > the more optimal format/modifier for the buffer allocation. The > client must explicitely inform the server that it understands > this mode by adding the PresentOptionSuboptimal flag when calling > PresentPixmap. > > Its main usage as of now is to allow clients to re-fetch DRI3 > format modifiers as some modifiers might allow direct scanout. > > Bump presentproto version to 1.2. > > Signed-off-by: Louis-Francis Ratté-Boulianne <[email protected]> > Reviewed-by: Daniel Stone <[email protected]>
Merged: To ssh://git.freedesktop.org/git/xorg/proto/xorgproto 29c53a2..751cf1e master -> master Still need to wire xorgproto up to patchwork, it seems. - ajax _______________________________________________ [email protected]: X.Org development Archives: http://lists.x.org/archives/xorg-devel Info: https://lists.x.org/mailman/listinfo/xorg-devel