On 24.10.2023 12:26, Roger Pau Monne wrote:
> The ACPI FADT APIC_CLUSTER flag mandates that when the interrupt delivery is
> Logical mode APIC must be configured for Cluster destination model.  However 
> in
> apic_x2apic_probe() such flag is incorrectly used to gate whether Physical 
> mode
> can be used.
> 
> Since Xen when in x2APIC mode only uses Logical mode together with Cluster
> model completely remove checking for ACPI_FADT_APIC_CLUSTER, as Xen always
> fulfills the requirement signaled by the flag.

Actually, one remark: The text in the 6.5 spec really only mentions xAPIC
mode, so it's not entirely clear whether the two flags actually have any
meaning for x2APIC mode.

Jan