On Fri, 2022-10-21 at 12:39 +0200, Juergen Gross wrote: > Instead of directly falling back to the idle unit in case the top > unit from the run queue happened to be not runnable, consult the run > queue again. > > Suggested-by: Dario Faggioli <[email protected]> > Signed-off-by: Juergen Gross <[email protected]> > Reviewed-by: Dario Faggioli <[email protected]>
And thanks for making the patch! :-) Regards -- Dario Faggioli, Ph.D http://about.me/dario.faggioli Virtualization Software Engineer SUSE Labs, SUSE https://www.suse.com/ ------------------------------------------------------------------- <<This happens because _I_ choose it to happen!>> (Raistlin Majere)
signature.asc
Description: This is a digitally signed message part
