>From window event viewer at startup
*-* *System* *-* *Provider* [ *Name*] VisualSVN *-* *EventID* 1000 [ *Qualifiers*] 0 *Level* 2 *Task* 0 *Keywords* 0x80000000000000 *-* *TimeCreated* [ *SystemTime*] 2014-05-19T17:53:24.000000000Z *EventRecordID* 22367 *Channel* Application *Computer* *Security* *-* *EventData* Unexpected exception: VisualSVN worker process has abnormally terminated with the exit code 0x40010004. For further details please check the Event Log. at ManagedSVN.WorkerProcess.DoReadInt32() at ManagedSVN.Client.GetStatus(String path, Boolean recurse, Boolean getAll, Boolean noIgnore, Boolean ignoreExternals, GetStatusCallback callback) at VisualSVN.Core.FileStatusReceiver..ctor(Client client, String path, Boolean recursive) at VisualSVN.Core.StatusUpdater.LoadStatus(String[] paths) Unexpected exception: Unable to read beyond the end of the stream. at System.IO.BinaryReader.FillBuffer(Int32 numBytes) at System.IO.BinaryReader.ReadInt32() at ManagedSVN.WorkerProcess.DoReadInt32() StackTrace: at System.Environment.GetStackTrace(Exception e, Boolean needFileInfo) at System.Environment.get_StackTrace() at VisualSVN.Utils.Log.ReportException(Exception ex) at VisualSVN.Core.StatusUpdater.LoadStatus(String[] paths) at VisualSVN.Core.StatusUpdater.ProcessImpl(IsCanceledCallback isCanceled) at VisualSVN.Core.StatusUpdater.Process(IsCanceledCallback isCanceled) at VisualSVN.Core.StatusManager.Work() at System.Threading.ThreadHelper.ThreadStart_Context(Object state) at System.Threading.ExecutionContext.RunInternal(ExecutionContext executionContext, ContextCallback callback, Object state, Boolean preserveSyncCtx) at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state, Boolean preserveSyncCtx) at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state) at System.Threading.ThreadHelper.ThreadStart() Regards, Rich Messenger Principal Engineer *NxStage Medical, Inc.* 350 Merrimack Street Lawrence, MA 01843 Tel: (978) 687-4756 Fax: (978) 687-4800 rmessen...@nxstage.com This email transmission is intended only for the use of the individual to which it is addressed and may contain information that is privileged, confidential, and exempt from disclosure under applicable law. If the reader of this message is not the intended recipient, you are hereby notified that any dissemination, distribution, or copying of this communication is strictly prohibited. If you have received this communication in error, please notify me immediately by replying to this message or by contacting NxStage at 978-687-4700 and destroy all copies of this message and any attachments without reading or disclosing their content. Thank you.