Hi! Common pitfall: The default parameters in the RA's metadata are not the defaults being configured when you don't specify a value; instead they are suggestions for you when configuring (don't ask me why!). Instead there is a global default timeout being used when you don't specify one. I hope I put that correctly. You could verify by manually adding the default avlues from the metadata to "demote".
Regards, Ulrich >>> Marc Smith <[email protected]> schrieb am 10.01.2018 um 16:26 in Nachricht <CAKdCJ==ABfaKgsL4awK=vy_90pmamhrek6exxnazdplgx2a...@mail.gmail.com>: > Hi, > > I'm experiencing a time out on a demote operation and I'm not sure > which parameter / attribute needs to be updated to extend the time out > window. > > I'm using Pacemaker 1.1.16 and Corosync 2.4.2. > > Here are the set of log lines that show the issue (shutdown initiated, > then demote time out after 20 seconds): > --snip-- > Jan 10 09:08:13 tgtnode2 pacemakerd[1096]: notice: Caught 'Terminated' > signal > Jan 10 09:08:13 tgtnode2 crmd[1104]: notice: Caught 'Terminated' signal > Jan 10 09:08:13 tgtnode2 crmd[1104]: notice: State transition S_IDLE > -> S_POLICY_ENGINE > Jan 10 09:08:13 tgtnode2 pengine[1103]: notice: Scheduling Node > tgtnode2.parodyne.com for shutdown > Jan 10 09:08:13 tgtnode2 pengine[1103]: notice: Promote > p_scst_zfs_vols:0^I(Slave -> Master tgtnode1.parodyne.com) > Jan 10 09:08:13 tgtnode2 pengine[1103]: notice: Demote > p_scst_zfs_vols:1^I(Master -> Stopped tgtnode2.parodyne.com) > Jan 10 09:08:13 tgtnode2 pengine[1103]: notice: Stop > p_dlm:1^I(tgtnode2.parodyne.com) > Jan 10 09:08:13 tgtnode2 pengine[1103]: notice: Migrate > p_dummy_g_zfs^I(Started tgtnode2.parodyne.com -> > tgtnode1.parodyne.com) > Jan 10 09:08:13 tgtnode2 pengine[1103]: notice: Move > p_zfs_pool_one^I(Started tgtnode2.parodyne.com -> > tgtnode1.parodyne.com) > Jan 10 09:08:13 tgtnode2 pengine[1103]: notice: Calculated > transition 3, saving inputs in > /var/lib/pacemaker/pengine/pe-input-1441.bz2 > Jan 10 09:08:13 tgtnode2 scst(p_scst_zfs_vols)[17449]: DEBUG: > scst_notify() -> Received a 'pre' / 'demote' notification. > Jan 10 09:08:13 tgtnode2 scst(p_scst_zfs_vols)[17449]: DEBUG: > p_scst_zfs_vols notify returned: 0 > Jan 10 09:08:13 tgtnode2 crmd[1104]: notice: Result of notify > operation for p_scst_zfs_vols on tgtnode2.parodyne.com: 0 (ok) > Jan 10 09:08:13 tgtnode2 scst(p_scst_zfs_vols)[17473]: DEBUG: > scst_monitor() -> SCST version: 3.3.0-rc > Jan 10 09:08:13 tgtnode2 scst(p_scst_zfs_vols)[17473]: DEBUG: > scst_monitor() -> Resource is running. > Jan 10 09:08:13 tgtnode2 scst(p_scst_zfs_vols)[17473]: DEBUG: > scst_monitor() -> SCST local target group state: active > Jan 10 09:08:13 tgtnode2 scst(p_scst_zfs_vols)[17473]: DEBUG: > scst_demote() -> Resource is currently running as Master. > Jan 10 09:08:13 tgtnode2 scst(p_scst_zfs_vols)[17473]: INFO: Blocking > all 'zfs_vols' devices... > Jan 10 09:08:13 tgtnode2 scst(p_scst_zfs_vols)[17473]: DEBUG: Waiting > for devices to finish blocking... > Jan 10 09:08:13 tgtnode2 scst(p_scst_zfs_vols)[17473]: DEBUG: > scst_demote() -> Setting target group 'zfs_vols_local' ALUA state to > 'transitioning'... > Jan 10 09:08:13 tgtnode2 scst(p_scst_zfs_vols)[17473]: INFO: > Collecting current configuration: done. -> Making requested changes. > -> Setting Target Group attribute 'state' to value 'transitioning' for > target group 'zfs_vols/zfs_vols_local': done. -> Done, 1 change(s) > made. All done. > Jan 10 09:08:13 tgtnode2 scst(p_scst_zfs_vols)[17473]: DEBUG: > scst_demote() -> Setting target group 'zfs_vols_local' ALUA state to > 'unavailable'... > Jan 10 09:08:13 tgtnode2 scst(p_scst_zfs_vols)[17473]: INFO: > Collecting current configuration: done. -> Making requested changes. > -> Setting Target Group attribute 'state' to value 'unavailable' for > target group 'zfs_vols/zfs_vols_local': done. -> Done, 1 change(s) > made. All done. > Jan 10 09:08:13 tgtnode2 scst(p_scst_zfs_vols)[17473]: DEBUG: > scst_demote() -> Changing the group's devices to inactive... > Jan 10 09:08:33 tgtnode2 lrmd[1101]: warning: > p_scst_zfs_vols_demote_0 process (PID 17473) timed out > Jan 10 09:08:33 tgtnode2 crmd[1104]: notice: Transition aborted by > operation p_scst_zfs_vols_demote_0 'modify' on tgtnode2.parodyne.com: > Event failed > Jan 10 09:08:33 tgtnode2 crmd[1104]: notice: Transition aborted by > status-2-fail-count-p_scst_zfs_vols doing create > fail-count-p_scst_zfs_vols=1: Transient attribute change > --snip-- > > So I'm getting a "time out" after 20 seconds of waiting in the demote > operation with this line: Jan 10 09:08:33 tgtnode2 lrmd[1101]: > warning: p_scst_zfs_vols_demote_0 process (PID 17473) timed out > > The 20 second time out is consistent when testing this, so I'm sure > it's just a configuration thing, but it's not obvious to me which > parameter/attribute/setting needs to be modified. > > The relevant metadata section from the RA referenced above: > --snip-- > <actions> > <action name="meta-data" timeout="5" /> > <action name="start" timeout="120" /> > <action name="stop" timeout="90" /> > <action name="monitor" timeout="20" depth="0" > interval="10" role="Master" /> > <action name="monitor" timeout="20" depth="0" > interval="20" role="Slave" /> > <action name="notify" timeout="20" /> > <action name="promote" timeout="60" /> > <action name="demote" timeout="60" /> > <action name="reload" timeout="20" /> > <action name="validate-all" timeout="20" /> > </actions> > --snip-- > > And the primitive and clone (multi-state) actual cluster configuration > for the referenced resource: > --snip-- > primitive p_scst_zfs_vols ocf:esos:scst \ > params alua=true device_group=zfs_vols local_tgt_grp=zfs_vols_local > remote_tgt_grp=zfs_vols_remote m_alua_state=active > s_alua_state=unavailable use_trans_state=true set_dev_active=true \ > op monitor interval=10 role=Master \ > op monitor interval=20 role=Slave \ > op start interval=0 timeout=120 \ > op stop interval=0 timeout=90 > ms ms_scst_zfs_vols p_scst_zfs_vols \ > meta master-max=1 master-node-max=1 clone-max=2 clone-node-max=1 > notify=true interleave=true > --snip-- > > I see a few values in the RA's metadata action section with "20 > seconds" and the interval parameter for the primitive, but I'm not > sure which might be affecting this demote time out setting. Any would > help be greatly appreciated. > > Thanks so much for your time! And thank you for a great software product! > > > --Marc > > _______________________________________________ > Users mailing list: [email protected] > http://lists.clusterlabs.org/mailman/listinfo/users > > Project Home: http://www.clusterlabs.org > Getting started: http://www.clusterlabs.org/doc/Cluster_from_Scratch.pdf > Bugs: http://bugs.clusterlabs.org _______________________________________________ Users mailing list: [email protected] http://lists.clusterlabs.org/mailman/listinfo/users Project Home: http://www.clusterlabs.org Getting started: http://www.clusterlabs.org/doc/Cluster_from_Scratch.pdf Bugs: http://bugs.clusterlabs.org