>From upstream: "So the problem is intel driver always assumes LVDS connected on mobile chipset. And in this case there's no local flat panel on this machine with 965GM.
We can work around it with adding a quirk. But I'm wondering if we can do better to completely resolve this kind of issues with adding LVDS detection code in the driver. For now I suggest users to work around it by explicitly disable LVDS in xorg.conf: 1) Add Option "monitor-LVDS" "LVDS" in Device section 2) Section "Monitor" Identifier "LVDS" Option "Ignore" "True" EndSection " Could somebody confirm this? ** Summary changed: - No display with Intel x3100 965GM Express + "Output LVDS is connected to pipe B" on a Mini-PC without LFP -- "Output LVDS is connected to pipe B" on a Mini-PC without LFP https://bugs.launchpad.net/bugs/233787 You received this bug notification because you are a member of Ubuntu Bugs, which is subscribed to Ubuntu. -- ubuntu-bugs mailing list ubuntu-bugs@lists.ubuntu.com https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs