Following fixed it for me: @@ -579,7 +579,7 @@ procdata->config.show_kill_warning); g_signal_connect (G_OBJECT (check_button), "toggled", G_CALLBACK (show_kill_dialog_toggled), procdata); - gtk_box_pack_start (GTK_BOX (hbox2), check_button, FALSE, FALSE, 0); + gtk_box_pack_start (GTK_BOX (hbox2), check_button, TRUE, TRUE, 0); @@ -725,7 +725,7 @@ procdata->config.show_all_fs); g_signal_connect (G_OBJECT (check_button), "toggled", G_CALLBACK (show_all_fs_toggled), procdata); - gtk_box_pack_start (GTK_BOX (hbox2), check_button, FALSE, FALSE, 0); + gtk_box_pack_start (GTK_BOX (hbox2), check_button, TRUE, TRUE, 0);
I know that this kind of problems have the lowest priority, but a desktop OS should really have a polished GUI. -- Inconsistent mouseover behaviour in System Monitor Preferences https://bugs.launchpad.net/bugs/203371 You received this bug notification because you are a member of Ubuntu Bugs, which is subscribed to Ubuntu. -- ubuntu-bugs mailing list ubuntu-bugs@lists.ubuntu.com https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs