Can you test using this configuration of Pacemaker ? :

primitive p_percona ocf:heartbeat:galera \
        params 
wsrep_cluster_address="gcomm://controller-1,controller-2,controller-3" \
        params config="/etc/mysql/my.cnf" \
        params datadir="/var/lib/percona-xtradb-cluster" \
        params socket="/var/run/mysqld/mysqld.sock" 
pid="/var/run/mysqld/mysqld.pid" \
        params check_user=root check_passwd=****** \
        params binary="/usr/bin/mysqld_safe" \
        op monitor timeout=120 interval=20 depth=0 \
        op monitor role=Master timeout=120 interval=10 depth=0 \
        op monitor role=Slave timeout=120 interval=30 depth=0
ms ms_percona p_percona \
        meta notify=true interleave=true \
        meta master-max=3 \
        meta ordered=true target-role=Started

-- 
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/1789527

Title:
  Galera agent doesn't work when grastate.dat contains safe_to_bootstrap

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/resource-agents/+bug/1789527/+subscriptions

-- 
ubuntu-bugs mailing list
ubuntu-bugs@lists.ubuntu.com
https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs