Public bug reported: This is an additional change following after the m800 bug (LP: #1347776) and m400 bug (LP: #1354306), udev/systemd needs a rule to cover triggering a graceful shutdown on the HP Proliant m400 Cartridge when running the utopic hwe kernel in trusty.
[Impact] Currently, graceful shutdown via the iLO works when running the base trusty kernel, but if the hwe kernel is installed, it stops. [Test Case] Initiate a graceful shutdown via the iLO. [Regression Potential] The new rule is pretty tightly bound to the m400 system - so the risk of this rule matching and impacting behavior on a different platform is minimal. This will presumably cause new code to run and read /proc/device-tree/model on other platforms - but this is already done for the m800 system in both utopic and trusty as well as the 3.13.0 kernel m400 rule. ** Affects: systemd (Ubuntu) Importance: Undecided Status: New -- You received this bug notification because you are a member of Ubuntu Bugs, which is subscribed to Ubuntu. https://bugs.launchpad.net/bugs/1428811 Title: Trusty hwe kernel (utopic) gpio shutdown trigger for ProLiant m400 cartridges To manage notifications about this bug go to: https://bugs.launchpad.net/ubuntu/+source/systemd/+bug/1428811/+subscriptions -- ubuntu-bugs mailing list ubuntu-bugs@lists.ubuntu.com https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs