Confirmed ****NOT A KERNEL Bug****.
Ran the following test:
1) Installed ethtool.
2) Ran command sudo ethtool -s eth0 wol d
3) Checked WOL:
sudo ethtool eth0 | grep Wake-on
[sudo] password for dave: 
        Supports Wake-on: pumbg
        Wake-on: d
3) Fully charged Eny Sleekbook, powered down, waited 48hrs (2days).

Test Result
4) Powered up Sleekbook on battery immediately took battery reading:

http://www.divnut.com/Ubuntu/Battery_48hr_test_010212.png

Measured Battery charge state: 96.3%  battery depletion ~1.7% in over days 
allowing ~1-2% for boot up on Battery.
Was previously 36% 

Big thanks to Raymond Dalgleish for his input.

So the fix is ethtool requires to be part of the default Unbuntu install
with default WOL set off.

@Joseph Salisbury suggest this bug is closed, on what would I raise a
new bug to progress the fix ?