Public bug reported: It looks like the bug #871278 is still present in NexentaStor driver.
I'm using Ubuntu 12.04.1 64bit with cinder-volumes package 2012.2-0ubuntu2~cloud0 and if I try to attach cinder volume to an instance, it fails with the following error in nova-compute.log: 2012-12-05 16:10:26 TRACE Error: iSCSI device not found at /dev/disk/by- path/ip-10.1.0.2:3260-iscsi-iqn.1986-03.com.sun:02:cinder- volume-0000001-lun-1 However the file /dev/disk/by-path/ip-10.1.0.2:3260-iscsi- iqn.1986-03.com.sun:02:cinder-volume-0000001-lun-0 exists. So if I do ln -s /dev/disk/by-path/ip-10.1.0.2:3260-iscsi-iqn.1986-03.com.sun:02 :cinder-volume-0000001-lun-0 /dev/disk/by-path/ip-10.1.0.2:3260-iscsi- iqn.1986-03.com.sun:02:cinder-volume-0000001-lun-1 everything works. I fixed it by changing line 232 in /usr/share/pyshared/cinder/volume/nexenta/volume.py from 'lun': '0'}) to 'lun': '1'}) ** Affects: cinder (Ubuntu) Importance: Undecided Status: New ** Summary changed: - Cannot attach volumes to instances if using NexentaStror driver + Cannot attach volumes to instances if using NexentaStor driver -- You received this bug notification because you are a member of Ubuntu Bugs, which is subscribed to Ubuntu. https://bugs.launchpad.net/bugs/1088411 Title: Cannot attach volumes to instances if using NexentaStor driver To manage notifications about this bug go to: https://bugs.launchpad.net/ubuntu/+source/cinder/+bug/1088411/+subscriptions -- ubuntu-bugs mailing list ubuntu-bugs@lists.ubuntu.com https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs