Public bug reported:

On PXE installation of the latest Ubuntu 11.10 on a Dell R410 with a
PERC H700 RAID card the disks are recognised by the megaraid_sas driver.
However this appears not to happen fast enough for the disk-detect
script and so the automated install is stopped asking which storage
driver to use because no storage is found.

Because the storage has been found selecting any driver will work and
install continues and finishes successfully.

Having had a look at the disk-detect script it would appear since there
is already a sleep loop in there all that would need to changed to fix
this bug is to increase the sleep timeout or number of loops in disk-
detect.

** Affects: hw-detect (Ubuntu)
     Importance: Undecided
         Status: New

-- 
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/956850

Title:
  H700 raid card in Dell R410 does not provide access to storage quick
  enough for disk-detect

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/hw-detect/+bug/956850/+subscriptions

-- 