Just to clarify the problems i have seen and what my test has fixed.

On the aspire one the charge is correctly reported from boot  until the charge 
is full. 
Then if you remove the powercord gnome power manager reports full charge until 
the battery dies.
This is due to the fact that upower stops polling the battery when the charge 
is full.
upower has a poll of the battery on changes in the ac supply but when the 
battery is fully charged it takes a while for it to start reporting that it is 
discharging so the automatic polls around ac power event does not catch this 
and it disables the polling of the battery.

restaring upowerd or plugging in the AC power will remedy this, provided
the battery isn't full yet.

-- 
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/467825

Title:
  Battery state always "fully charged"

To manage notifications about this bug go to:
https://bugs.launchpad.net/gnome-power/+bug/467825/+subscriptions

-- 