Here's the output of scanimage. Did I mention that the preview is
perfect? The issue is the output to PDF.


br-y' => '279'
                                                                             },
                                                                             {
                                                                               
'mode' => 'Lineart'
                                                                             },
                                                                             {
                                                                               
'resolution' => '200'
                                                                             }
                                                                           ],
                         'genesys:libusb:006:005' => [
                                                       {
                                                         'br-y' => '279'
                                                       },
                                                       {
                                                         'resolution' => '150'
                                                       }
                                                     ],
                         'genesys:libusb:006:004' => [
                                                       {
                                                         'mode' => 'Color'
                                                       },
                                                       {
                                                         'br-x' => 
'215.899993896484'
                                                       },
                                                       {
                                                         'br-y' => '279'
                                                       },
                                                       {
                                                         'clear-calibration' => 
undef
                                                       }
                                                     ]
                       },
          'window_height' => '690',
          'rotate reverse' => '0',
          'Dark threshold' => '0.12',
          'pages to scan' => '1',
          'resolution' => '300',
          'Blank threshold' => '0.005',
          'unpaper on scan' => '1',
          'libsane-perl version' => '0.03',
          'x' => '215.9',
          'downsample dpi' => '150',
          'window_width' => '1024',
          'deskew-scan-direction' => 'left,top',
          'threshold tool' => '70',
          'unsharp sigma' => '1',
          'thumb panel' => '155',
          'border-align' => 'left,top',
          'unsharp threshold' => '0.05',
          'l' => '0',
          'SANE version' => '1.0.21',
          'no-mask-scan' => '1',
          'downsample' => '',
          'restore window' => '1',
          'batch-scan' => 'no',
          'pdf compression' => 'none'
        };
Found Image::Magick
Found ImageMagick
Found scanadf
Found xdg-email
Found gocr
Found tesseract
Found cuneiform
Found cjb2 (djvu)
Found unpaper
Found libtiff
Using /tmp/LsUJLwCuEq for temporary files
Using tessdata at /usr/share/tesseract-ocr/tessdata
cuneiform -l
Cuneiform for Linux 0.7.0
Supported languages: eng ger fra rus swe spa ita ruseng ukr srp hrv pol dan por 
dut cze rum hun bul slo lav lit est tur.
 scanimage --formatted-device-list="'%i','%d','%v %m'
" 2>/dev/null
Forked PID 8081
Waiting to reap process at /usr/bin/gscan2pdf line 4990.
Reaped PID -1
'0','genesys:libusb:006:002','Hewlett Packard ScanJet 2300c'
$VAR1 = {
          'source' => {
                        'tip' => 'Selects the scan source (such as a 
document-feeder).',
                        'default' => 'Flatbed',
                        'values' => [
                                      'Flatbed'
                                    ]
                      },
          'mode' => {
                      'tip' => 'Selects the scan mode (e.g., lineart, 
monochrome, or color).',
                      'default' => 'Lineart',
                      'values' => [
                                    'Color',
                                    'Gray',
                                    'Lineart'
                                  ]
                    },
          'extend-lamp-timeout' => {
                                     'tip' => 'Extends lamp timeout (from 15 
minutes to 1 hour)',
                                     'default' => 'no',
                                     'values' => [
                                                   'yes',
                                                   'no'
                                                 ]
                                   },
          'x' => {
                   'tip' => 'Width of scan-area.',
                   'step' => '0.0999908',
                   'unit' => 'mm',
                   'min' => '0',
                   'max' => '215.889',
                   'default' => '215.889'
                 },
          'l' => {
                   'tip' => 'Top-left x position of scan area.',
                   'step' => '0.0999908',
                   'unit' => 'mm',
                   'min' => '0',
                   'max' => '215.889',
                   'default' => '0'
                 },
          'y' => {
                   'tip' => 'Height of scan-area.',
                   'step' => '0.0999908',
                   'unit' => 'mm',
                   'min' => '0',
                   'max' => '297.699',
                   'default' => '297.699'
                 },
          'preview' => {
                         'tip' => 'Request a preview-quality scan.',
                         'default' => 'no',
                         'values' => [
                                       'yes',
                                       'no'
                                     ]
                       },
          'resolution' => {
                            'tip' => 'Sets the resolution of the scanned 
image.',
                            'unit' => 'dpi',
                            'default' => '100',
                            'values' => [
                                          '100',
                                          '200',
                                          '300',
                                          '600',
                                          '1200',
                                          '2400'
                                        ]
                          },
          't' => {
                   'tip' => 'Top-left y position of scan area.',
                   'step' => '0.0999908',
                   'unit' => 'mm',
                   'min' => '0',
                   'max' => '297.699',
                   'default' => '0'
                 },
          'wait-for-button' => {
                                 'tip' => 'Waits for button before scanning',
                                 'default' => 'no',
                                 'values' => [
                                               'yes',
                                               'no'
                                             ]
                               }
        };
 scanimage --help --device-name='genesys:libusb:006:002' --mode='Gray'
Forked PID 8084
Waiting to reap process at /usr/bin/gscan2pdf line 8024.
Reaped PID -1
Usage: scanimage [OPTION]...

Start image acquisition on a scanner device and write image data to
standard output.

Parameters are separated by a blank from single-character options (e.g.
-d epson) and by a "=" from multi-character options (e.g. --device-name=epson).
-d, --device-name=DEVICE   use a given scanner device (e.g. hp:/dev/scanner)
    --format=pnm|tiff      file format of output file
-i, --icc-profile=PROFILE  include this ICC profile into TIFF file
-L, --list-devices         show available scanner devices
-f, --formatted-device-list=FORMAT similar to -L, but the FORMAT of the output
                           can be specified: %d (device name), %v (vendor),
                           %m (model), %t (type), %i (index number), and
                           %n (newline)
-b, --batch[=FORMAT]       working in batch mode, FORMAT is `out%d.pnm' or
                           `out%d.tif' by default depending on --format
    --batch-start=#        page number to start naming files with
    --batch-count=#        how many pages to scan in batch mode
    --batch-increment=#    increase page number in filename by #
    --batch-double         increment page number by two, same as
                           --batch-increment=2
    --batch-prompt         ask for pressing a key before scanning a page
    --accept-md5-only      only accept authorization requests using md5
-p, --progress             print progress messages
-n, --dont-scan            only set options, don't actually scan
-T, --test                 test backend thoroughly
-h, --help                 display this help message and exit
-v, --verbose              give even more status messages
-B, --buffer-size=#        change input buffer size (in kB, default 32)
-V, --version              print version information

Options specific to device `genesys:libusb:006:002':
  Scan Mode:
    --mode Color|Gray|Lineart [Gray]
        Selects the scan mode (e.g., lineart, monochrome, or color).
    --source Flatbed|Transparency Adapter [inactive]
        Selects the scan source (such as a document-feeder).
    --preview[=(yes|no)] [no]
        Request a preview-quality scan.
    --depth 8|16 [8]
        Number of bits per sample, typical values are 1 for "line-art" and 8
        for multibit scans.
    --resolution 1200|600|300|150|75dpi [300]
        Sets the resolution of the scanned image.
  Geometry:
    -l 0..215.9mm [0]
        Top-left x position of scan area.
    -t 0..295mm [0]
        Top-left y position of scan area.
    -x 0..215.9mm [215.9]
        Width of scan-area.
    -y 0..295mm [295]
        Height of scan-area.
  Enhancement:
    --custom-gamma[=(yes|no)] [no]
        Determines whether a builtin or a custom gamma-table should be used.
    --gamma-table 0..16383,... [inactive]
        Gamma-correction table.  In color mode this option equally affects the
        red, green, and blue channels simultaneously (i.e., it is an intensity
        gamma table).
    --red-gamma-table 0..16383,... [inactive]
        Gamma-correction table for the red band.
    --green-gamma-table 0..16383,... [inactive]
        Gamma-correction table for the green band.
    --blue-gamma-table 0..16383,... [inactive]
        Gamma-correction table for the blue band.
  Extras:
    --lamp-off-time 0..60 [15]
        The lamp will be turned off after the given time (in minutes). A value
        of 0 means, that the lamp won't be turned off.
    --threshold 0..100% (in steps of 1) [inactive]
        Select minimum-brightness to get a white point
    --threshold-curve 0..127 (in steps of 1) [inactive]
        Dynamic threshold curve, from light to dark, normally 50-65
    --disable-dynamic-lineart[=(yes|no)] [inactive]
        Disabel use of a software adaptative algorithm to generate lineart
        instead of relying on hardware lineart
    --disable-interpolation[=(yes|no)] [no]
        When using high resolutions where the horizontal resolution is smaller
        than the vertical resolution this disables horizontal interpolation.
    --color-filter Red|Green|Blue [Green]
        When using gray or lineart this option selects the used color.
  Sensors:
    --scan[=(yes|no)] [no] [hardware]
        Scan button
    --copy[=(yes|no)] [no] [hardware]
        Copy button
  Buttons:
    --clear-calibration []
        Clear calibration cache

Type ``scanimage --help -d DEVICE'' to get list of all options for
DEVICE.

List of available devices:
    genesys:libusb:006:002
$VAR1 = {
          'source' => {
                        'tip' => 'Selects the scan source (such as a 
document-feeder).',
                        'default' => 'inactive',
                        'values' => [
                                      'Flatbed',
                                      'Transparency Adapter'
                                    ]
                      },
          'gamma-table' => {
                             'tip' => 'Gamma-correction table.  In color mode 
this option equally affects the red, green, and blue channels simultaneously 
(i.e., it is an intensity gamma table).',
                             'min' => '0',
                             'max' => '16383',
                             'default' => 'inactive'
                           },
          'lamp-off-time' => {
                               'tip' => 'The lamp will be turned off after the 
given time (in minutes). A value of 0 means, that the lamp won\'t be turned 
off.',
                               'min' => '0',
                               'max' => '60',
                               'default' => '15'
                             },
          'clear-calibration' => {
                                   'tip' => 'Clear calibration cache',
                                   'default' => ''
                                 },
          'threshold' => {
                           'tip' => 'Select minimum-brightness to get a white 
point',
                           'step' => '1',
                           'unit' => '%',
                           'min' => '0',
                           'max' => '100',
                           'default' => 'inactive'
                         },
          'disable-dynamic-lineart' => {
                                         'tip' => 'Disabel use of a software 
adaptative algorithm to generate lineart instead of relying on hardware 
lineart',
                                         'default' => 'inactive',
                                         'values' => [
                                                       'yes',
                                                       'no'
                                                     ]
                                       },
          'mode' => {
                      'tip' => 'Selects the scan mode (e.g., lineart, 
monochrome, or color).',
                      'default' => 'Gray',
                      'values' => [
                                    'Color',
                                    'Gray',
                                    'Lineart'
                                  ]
                    },
          'red-gamma-table' => {
                                 'tip' => 'Gamma-correction table for the red 
band.',
                                 'min' => '0',
                                 'max' => '16383',
                                 'default' => 'inactive'
                               },
          'green-gamma-table' => {
                                   'tip' => 'Gamma-correction table for the 
green band.',
                                   'min' => '0',
                                   'max' => '16383',
                                   'default' => 'inactive'
                                 },
          'x' => {
                   'tip' => 'Width of scan-area.',
                   'unit' => 'mm',
                   'min' => '0',
                   'max' => '215.9',
                   'default' => '215.9'
                 },
          'custom-gamma' => {
                              'tip' => 'Determines whether a builtin or a 
custom gamma-table should be used.',
                              'default' => 'no',
                              'values' => [
                                            'yes',
                                            'no'
                                          ]
                            },
          'y' => {
                   'tip' => 'Height of scan-area.',
                   'unit' => 'mm',
                   'min' => '0',
                   'max' => '295',
                   'default' => '295'
                 },
          'copy' => {
                      'tip' => 'Copy button',
                      'default' => 'hardware',
                      'values' => [
                                    'yes',
                                    'no'
                                  ]
                    },
          'color-filter' => {
                              'tip' => 'When using gray or lineart this option 
selects the used color.',
                              'default' => 'Green',
                              'values' => [
                                            'Red',
                                            'Green',
                                            'Blue'
                                          ]
                            },
          't' => {
                   'tip' => 'Top-left y position of scan area.',
                   'unit' => 'mm',
                   'min' => '0',
                   'max' => '295',
                   'default' => '0'
                 },
          'blue-gamma-table' => {
                                  'tip' => 'Gamma-correction table for the blue 
band.',
                                  'min' => '0',
                                  'max' => '16383',
                                  'default' => 'inactive'
                                },
          'depth' => {
                       'tip' => 'Number of bits per sample, typical values are 
1 for "line-art" and 8 for multibit scans.',
                       'default' => '8',
                       'values' => [
                                     '8',
                                     '16'
                                   ]
                     },
          'disable-interpolation' => {
                                       'tip' => 'When using high resolutions 
where the horizontal resolution is smaller than the vertical resolution this 
disables horizontal interpolation.',
                                       'default' => 'no',
                                       'values' => [
                                                     'yes',
                                                     'no'
                                                   ]
                                     },
          'l' => {
                   'tip' => 'Top-left x position of scan area.',
                   'unit' => 'mm',
                   'min' => '0',
                   'max' => '215.9',
                   'default' => '0'
                 },
          'scan' => {
                      'tip' => 'Scan button',
                      'default' => 'hardware',
                      'values' => [
                                    'yes',
                                    'no'
                                  ]
                    },
          'preview' => {
                         'tip' => 'Request a preview-quality scan.',
                         'default' => 'no',
                         'values' => [
                                       'yes',
                                       'no'
                                     ]
                       },
          'threshold-curve' => {
                                 'tip' => 'Dynamic threshold curve, from light 
to dark, normally 50-65',
                                 'step' => '1',
                                 'min' => '0',
                                 'max' => '127',
                                 'default' => 'inactive'
                               },
          'resolution' => {
                            'tip' => 'Sets the resolution of the scanned 
image.',
                            'unit' => 'dpi',
                            'default' => '300',
                            'values' => [
                                          '1200',
                                          '600',
                                          '300',
                                          '150',
                                          '75'
                                        ]
                          }
        };
$VAR1 = [];
$VAR1 = {
          'l' => '0',
          'y' => '279',
          'Paper size' => 'US Letter',
          'mode' => 'Gray',
          'resolution' => '300',
          'x' => '215.889',
          't' => '0'
        };
rotate facing 0
rotate reverse 0
non-duplex mode
rotate_facing 0
rotate_reverse 0
unpaper 1
OCR 
 scanimage --device-name='genesys:libusb:006:002' --mode='Gray' -y 279 -l 0 
--resolution='300' -x 215.889 -t 0 --batch --progress --batch-count=1
Forked PID 8088
Scanning 1 pages, incrementing by 1, numbering from 1
Scanning page 1
Scanned page 1. (scanner status = 5)
Format is P5
Header is 37
Header suggests 8398992
Expecting 8398992, found 8398992
Importing out1.pnm, format Portable anymap
Added /tmp/LsUJLwCuEq/SOmLsJa3cj.pnm at page 1 with resolution 300
Waiting to reap process at /usr/bin/gscan2pdf line 6162.
Reaped PID 8088
unpaper --no-blackfilter --border-align left,top --output-pages 1 
--no-blurfilter --no-noisefilter --white-threshold 0.9 --layout single 
--no-mask-scan --no-grayfilter --black-threshold 0.33 --deskew-scan-direction 
left,top --overwrite --input-file-sequence /tmp/LsUJLwCuEq/SOmLsJa3cj.pnm 
--output-file-sequence /tmp/LsUJLwCuEq/mwTmeIAae5.pnm ;
Forked PID 8090
Processing sheet: /tmp/LsUJLwCuEq/SOmLsJa3cj.pnm -> 
/tmp/LsUJLwCuEq/mwTmeIAae5.pnm
Waiting to reap process at /usr/bin/gscan2pdf line 10566.
Reaped PID -1
Forked PID 8097
Defining page at 611.76pt x 790.8pt
Adding /tmp/LsUJLwCuEq/mwTmeIAae5.pnm at 300 dpi
Process 8097 exited.
Exiting via sane_exit

-- 
PDF is split in grayscale
https://bugs.launchpad.net/bugs/619187
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.

-- 
ubuntu-bugs mailing list
ubuntu-bugs@lists.ubuntu.com
https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs

Reply via email to