Public bug reported: Binary package hint: conky
ctr...@jupiter:~$ lsb_release -d Description: Ubuntu karmic (development branch) ctr...@jupiter:~$ apt-cache policy conky conky: Installed: (none) Candidate: 1.7.2-0ubuntu1 Version table: 1.7.2-0ubuntu1 0 500 http://pt.archive.ubuntu.com karmic/universe Packages 100 /var/lib/dpkg/status When I add the following line in .conkyrc to get my cpu temperature from hwmon: CPU Temp: ${hwmon 0 temp 1}°Cr I get the following error when starting conky: Conky: can't open '/sys/class/hwmon/hwmon0/device/temp1_input': No such file or directory please check your device or remove this var from Conky Conky: X Error: type 0 Display 9ee7788 XID 0 serial 25 error_code 3 request_code 61 minor_code 0 other Display: 9ee7788 Aborted (core dumped) What I think is happening Conky is looking in the wrong place because there is nothing in /sys/class/hwmon/hwmon0/device/temp1_input: ctr...@jupiter:~$ cat /sys/class/hwmon/hwmon0/device/temp1_input cat: /sys/class/hwmon/hwmon0/device/temp1_input: No such file or directory and the file with the temperature information is actually in /sys/class/hwmon/hwmon0/temp1_input as you can see here: ctr...@jupiter:~$ cat /sys/class/hwmon/hwmon0/temp1_input 34000 ctr...@jupiter:~$ cat /sys/class/hwmon/hwmon0/temp1_label CPU Temperature ** Affects: conky (Ubuntu) Importance: Undecided Status: New -- Conky looks in the wrong sysfs dir for hwmon temperature info https://bugs.launchpad.net/bugs/435571 You received this bug notification because you are a member of Ubuntu Bugs, which is subscribed to Ubuntu. -- ubuntu-bugs mailing list ubuntu-bugs@lists.ubuntu.com https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs