** Changed in: linux (Ubuntu Intrepid)
       Status: In Progress => Fix Committed

** Description changed:

  My rt73 based DLink DWA-110 USB stick had no problem under Hardy
  2.6.24-19, so this seems to be a regression.
  
  The connection initially works fine. However, under load the connection
  locks up - the system tray icon shows signal but there is no network
  traffic going in or out. Running sudo
  /etc/dbus-1/event.d/25NetworkManager restart restarts network manager
  but the connection will no longer connect to the network. Rebooting the
  machine gets me connected again.
  
  This is easily reproducible - I just need to fire up a Bittorrent client
  for a few minutes.
+ 
+ ===
+ 
+ SRU Justification
+ 
+ Impact: high network load leads to loss of connectivity, a reboot is
+ required to recover
+ 
+ Fix Description: switches to former atomic operations
+ 
+ Patch: http://kernel.ubuntu.com/git?p=ubuntu/ubuntu-
+ intrepid.git;a=commit;h=a52e017788f9ab062372bf1a27107101ad46e733
+ 
+ Risks: this is a driver specific change
+ 
+ TEST CASE: see bug report

-- 
Ralink rt73 hangs and requires reboot
https://bugs.launchpad.net/bugs/258985
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.

-- 
ubuntu-bugs mailing list
ubuntu-bugs@lists.ubuntu.com
https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs

Reply via email to