Hi,

The card and cables don't have the signaling lines, that getty to use it
as com(4).  But with "local" in ttys(5) it works.  I have this driver in
productive use for about 5 years now.

OK?

bye,
Jan

Index: arch/amd64/conf/GENERIC
===================================================================
RCS file: /cvs/src/sys/arch/amd64/conf/GENERIC,v
retrieving revision 1.499
diff -u -p -r1.499 GENERIC
--- arch/amd64/conf/GENERIC     20 Aug 2021 05:23:18 -0000      1.499
+++ arch/amd64/conf/GENERIC     2 Sep 2021 08:49:22 -0000
@@ -403,7 +403,7 @@ com*        at pcmcia?                      # PCMCIA 
modems/serial
 com*   at puc?
 
 # options CY_HW_RTS
-#cy*   at pci?                         # PCI cyclom serial card
+cy*    at pci?                         # PCI cyclom serial card
 #cz*   at pci?                         # Cyclades-Z multi-port serial boards
 
 lpt0   at isa? port 0x378 irq 7        # standard PC parallel ports