Hi, Today I downloaded all my dives (since the Shearwater upgrade) with the latest qt-6 nightly, including the libdivecomputer log (see attached). I’ve added all of them to give logs with different tanks, gas mixes and usage.
Sunday I had a dive with a “close call” (feel free to ask details off-list) where I actually had to do a bailout on two gasses. So the log from 03/12 should give a “nice” view of a CCR dive. Unfortunately Shearwaters own application makes it very hard to read the details that, especially now, I would like to look into. Hopefully this data helps a bit more. — Attilla > On 17 Mar 2023, at 09:21, Attilla de Groot via subsurface > <[email protected]> wrote: > > Hi, > > Last December Shearwater fixed an issue on the Petrel3 that put a lot of gas > changes in the dive log. This prevented from Subsurface / libdivecomputer to > even download the log from the Petrel. After I was able to download the logs, > I noticed that the HP sensors were not included as they were in the > Shearwater application. Jef has been so kind to commit a change that solves > this in libdivecomputer > (https://github.com/libdivecomputer/libdivecomputer/commit/78373d827be59ade15446c74ad660580fb04de73). > All pressure data is now included the libdivecomputer log (two HP sensors > and the transmitters in my case) as you can see in the attached output. > > I loaded it into subsurface, corrected the tank sizes and gas content. > Unfortunately it seems there are a few issues when looking at it in > Subsurface itself (and the data in the ssrf). The patch was also included in > the latest Subsurface nightly and I tried to import the dives directly, but > I’m seeing the same issues with these dives (and newer ones). > > - On some (dives 2,3 and 5) of the dives the O2 sensor appears to be missing > (or at least one of the HP sensors). See screenshots. > - On the dives it seems that only the start and end pressure data is > available for one of the HP sensors. E.g in dive5 I only see one sample/entry > with the pressure of tank2 and no entry for tank3. I guess this is the cause > for the “missing" sensor. > >> <dive number='5' otu='70' cns='26%' date='2023-01-29' time='09:33:07' >> duration='48:42 min'> >> <cylinder size='11.094 l' workpressure='206.843 bar' description='AL80' >> depth='22.294 m' /> >> <cylinder size='11.094 l' workpressure='206.843 bar' description='AL80' >> o2='50.0%' end='178.85 bar' depth='67.339 m' /> >> <cylinder size='3.0 l' workpressure='232.0 bar' description='3ℓ 232 bar' >> o2='19.0%' he='27.0%' start='181.056 bar' end='108.937 bar' depth='75.515 m' >> /> >> <cylinder size='3.0 l' workpressure='232.0 bar' description='3ℓ 232 bar' >> o2='100.0%' start='150.03 bar' end='104.938 bar' depth='67.706 m' /> >> ... >> >> <sample time='52:30 min' depth='0.0 m' pressure2='108.937 bar' /> > > - The gas usage in the graph is not plotted correctly, while the start and > end pressures are correct (see screenshot). I guess this is the result of the > above. > > > > Is this me doing something wrong or Subsurface not being able to handle > pressure data for multiple tanks at the same time? In the past I’ve done > dives with 4 transmitters and this seems to be available in the log and > plotted correctly (when the tanks are assigned to the right sensor). I would > expect to see something similar when I would import a dive from my Petrel3. > > > > — Attilla > _______________________________________________ > subsurface mailing list > [email protected] > http://lists.subsurface-divelog.org/cgi-bin/mailman/listinfo/subsurface _______________________________________________ subsurface mailing list [email protected] http://lists.subsurface-divelog.org/cgi-bin/mailman/listinfo/subsurface