> On Jun 22, 2018, at 9:19 PM, Davide DB <[email protected]> wrote:
> Great Dirk!
> This completely change everything. I always thought it would have delete
> everything.
> I will try ASAP.
Glad this addresses your problem.
> I would rather describe it as without the pretty icing on the cake.
> Every thing else about the profile is correct. Time, depth, temp and so
> on. The pO2 is just affecting your deco and the monitoring of your
> rebreather performance. Thats my view on it.
>
> I respect your point but I run my unit completely manual from the beginning
> so pO2 matters to me. It's a way to monitor my progress and see how the
> Shearwater Buhlmann behaves with the pO2 when I do not use ratio deco.
I don't care if it's no icing or the wrong icing, the point is that this is
less than we should (and can) show. We have a workaround in place. And I will
again reach out to Shearwater, now that I understand the issue a bit better.
> Two users affected in a very small Subsurface user base. Who knows how many
> units expose the default calibration values?
I don't think we have a way of knowing.
Thanks
/D