On 03 May, 2018 - Davide DB wrote: > On Wed, 2 May 2018 at 11:04, Anton Lundin <[email protected]> wrote: > > > > > Try to download them into a fresh logbook with the current desktop > > version, to see what's happens then. > > > > I've just downloaded my dives on a fresh Win10 4.7.8 installation. > As usual after few dives my Petrel quits with "error sending packet error". > I saved some of them anyway and PO2 values are missing. > This is how the petrel controller is recognized. File is attached. > > <divecomputer model='Shearwater Petrel 2' deviceid='1a2d46b1' > diveid='2e7067fb' dctype='CCR'> > > There's no mention of O2 sensor. > > These are all different pertel descriptions of the very same dive computer > I found in my original logbook > > <divecomputer model='Shearwater Petrel 2' deviceid='1a2d46b1' > diveid='3db7eb77' dctype='CCR' no_o2sensors='1'> > <divecomputer model='Shearwater Petrel 2' deviceid='1a2d46b1' > diveid='52d4ba3e' dctype='CCR' no_o2sensors='3'> > <divecomputer model='Shearwater Petrel' deviceid='1a2d46b1' > diveid='a6e05a10' dctype='CCR'> > <divecomputer model='Shearwater Petrel 2' deviceid='1a2d46b1' > diveid='3db24900' dctype='CCR'> > > Were pO2 samples download removed?
This is probably because we can't find any calibration values in your computer. Did you get a warning: "Disabled all O2 sensors due to a default calibration value." ? I think the code should fall back to the sensor average po2 when we won't get calibration values for the sensors, but we're not doing that right now. //Anton -- Anton Lundin +46702-161604 _______________________________________________ subsurface mailing list [email protected] http://lists.subsurface-divelog.org/cgi-bin/mailman/listinfo/subsurface