I noticed 2 things when testing: - Automerge is not triggered when importing additional dc from a Subsurface xml file (I fixed date and time manually for one dc on a separate xml that I then imported to my main log) - I have quite different deco calculations for different DCs on same dive. Subsurface calculates that I was still in deco when surfacing (ostc sport) while everything is ok for 2 different models of Suunto. Even while the ostc gives avg depth of 21.4 while Suuntos 21.7 and 22.1 meters. Of course this is visible on multiple other dives as well. I'll send a sample log to Dirk, Robert and Rick.
miika > On 3 Feb 2017, at 8.30, Salvador Cuñat <[email protected]> wrote: > > Good night. > > 2017-02-02 7:12 GMT+01:00 Willem Ferguson <[email protected]>: > >> >> >> b) Let's see if its possible to build an AppImage of the Scubapro SmartTrak >> import tool? I think Salva offered to look at that. > > I'am almost done with it. I've put a link with a test appimage in > Alessandro's thread you can try. It fails with a Xcb Qt plugins related > error on most systems I've tried, not all of them. Ideas about this would be > appreciated, as gooogled solutions are failing for me once and again. > BTW I've solved the localized time crash Dirk reported some days ago. Will > send the patches tomorrow. > > Regards. > > Salva. > _______________________________________________ > subsurface mailing list > [email protected] > http://lists.subsurface-divelog.org/cgi-bin/mailman/listinfo/subsurface
_______________________________________________ subsurface mailing list [email protected] http://lists.subsurface-divelog.org/cgi-bin/mailman/listinfo/subsurface