> On Jun 14, 2015, at 17:35, Linus Torvalds <[email protected]>
> wrote:
>
> On Sun, Jun 14, 2015 at 2:30 PM, Linus Torvalds
> <[email protected]> wrote:
>>
>> So this is the final piece to actually have working EON Steel
>> downloads with the new firmware. And actually tested too. Yay.
>
> Of course, since I had the pool dive (that didn't show the problem,
> because I didn't have any tank pressure readings for that), after I
> downloaded the thing, I wanted to remove the pool dive and re-number
> the actual dives.
>
> Which shows that renumbering selected dives got completely broken at
> some point. Tomaz?
>
> It does in fact renumber the selected dives, it's just that the
> renumbering starts from the first shown dive. Which is the most recent
> one. Which is *not* how dive numbering works. It's the *oldest*
> selected dive we should start the renumbering from.
>
> I think this used to work (just select a few dives, do the "renumber"
> thing from the menu, and give the starting number). I don't know when
> it broke, because I have not tried to do this in a long time.
My guess is it happened with the undo code.
Should be easy to fix
/D
_______________________________________________
subsurface mailing list
[email protected]
http://lists.subsurface-divelog.org/cgi-bin/mailman/listinfo/subsurface