Thanks for your reply. Well I'll change NodeName info as output of slurmd -C.
Yes, both Compute Node and ControlMachine are same machine for this first test setup. Should any other config parameter need in config file? thanks... On Tue, Aug 28, 2018 at 6:26 PM Raymond Wan <rwan.w...@gmail.com> wrote: > > Hi, > > > On Tuesday, August 28, 2018 09:43 PM, Umut Arus wrote: > > # COMPUTE NODES > > NodeName=umuta CPUs=1 State=UNKNOWN > > > I'm not sure what's the cause of your problem, but one thing > I noticed is that the line above should be replaced with the > output of the first line of "slurmd -C". > > The man pages of slurmd says: > > ----- > -C Print actual hardware configuration and exit. > The format of output is the same as used in slurm.conf to > describe a node's configuration plus it's uptime. > ----- > > Oh! I presume you have a value for ControlMachine in your > slurm.conf file? I think that is your "front end node". > > Ray > > > -- *Umut A.*